ez80f91 ZiLOG Semiconductor, ez80f91 Datasheet - Page 254

no-image

ez80f91

Manufacturer Part Number
ez80f91
Description
Ez80 Acclaimplus!? Connectivity Assp Ez80f91 Assp
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ez80f917050SBCG
Manufacturer:
Zilog
Quantity:
135
Part Number:
ez80f91AZ050EC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80f91AZ050EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80f91AZ050SC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80f91AZ050SG
Manufacturer:
Zilog
Quantity:
158
Part Number:
ez80f91AZ050SG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80f91AZA50EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80f91NA050SG
Manufacturer:
ZILOG
Quantity:
20 000
Company:
Part Number:
ez80f91NA050SG
Quantity:
160
eZ80F91 ASSP
Product Specification
246
Address Information for ZDI Address Match Registers
ZDI_ADDR0_L = 00h, ZDI_ADDR0_H = 01h, ZDI_ADDR0_U = 02h, ZDI_ADDR1_L =
04h, ZDI_ADDR1_H = 05h, ZDI_ADDR1_U = 06h, ZDI_ADDR2_L = 08h, ZDI_ADDR2_H
= 09h, ZDI_ADDR2_U = 0Ah, ZDI_ADDR3_L = 0Ch, ZDI_ADDR3_H = 0Dh, and
ZDI_ADDR3_U = 0Eh in the ZDI Register Write Only Address Space.
ZDI Break Control Register
The ZDI Break Control register is used to enable break points. ZDI asserts a break when
the CPU instruction address, ADDR[23:0], matches the value in the ZDI Address Match 3
registers, {ZDI_ADDR3_U, ZDI_ADDR3_H, ZDI_ADDR3_L}. BREAKs occurs only
on an instruction boundary. If the instruction address is not the beginning of an instruction
(that is, for multibyte instructions), then the break occurs at the end of the current instruc-
tion. The
bit is set to 1. The
bit must be reset to 0 to release the break.
brk_next
brk_next
See
Table 136
on page 247.