EP4SE530H40I3 Altera, EP4SE530H40I3 Datasheet - Page 921

no-image

EP4SE530H40I3

Manufacturer Part Number
EP4SE530H40I3
Description
IC STRATIX IV FPGA 530K 1517HBGA
Manufacturer
Altera
Series
STRATIX® IV Er

Specifications of EP4SE530H40I3

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
976
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1517-HBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SE530H40I3
Manufacturer:
ALTERA
Quantity:
325
Part Number:
EP4SE530H40I3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H40I3
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H40I3N
Manufacturer:
SHARP
Quantity:
1 200
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA
Quantity:
490
Part Number:
EP4SE530H40I3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4SE530H40I3N
0
Chapter 5: Dynamic Reconfiguration in Stratix IV Devices
Dynamic Reconfiguration Modes Implementation
Figure 5–38. Connecting the ALTGX and ALTGX_RECONFIG Instances with AEQ Enabled
February 2011 Altera Corporation
User Logic
reconfig_mode_sel[3:0]
Connections Between the ALTGX and ALTGX_RECONFIG Instances
Enable the adaptive equalization options in the ALTGX and ALTGX_RECONFIG
MegaWizard Plug-In Managers, as explained in the previous section. To use the AEQ
control block and AEQ hardware, you must connect the ALTGX receivers to the
ALTGX_RECONFIG instance using the reconfig_{to/from}gxb and
aeq_{to/from}gxb ports. You must also connect the ALTGX_RECONFIG instance to
your design.
If you have multiple transceiver instances and a single ALTGX_RECONFIG instance,
connect the LSB of the aeq_togxb[] and aeq_fromgxb[] ports of the
ALTGX_RECONFIG instance to the transceiver channel with a
logical_channel_address value of 0.
Figure 5–38
ALTGX instances and the dynamic reconfiguration controller.
ALTGX_RECONFIG
AEQ Control
shows the aeq_fromgxb[] and aeq_togxb[] connections between multiple
Block
aeq_togxb[23:0]
aeq_togxb[63:48]
aeq_fromgxb[23:16]
aeq_fromgxb[7:0]
aeq_fromgxb[15:8]
aeq_togxb[47:24]
busy
error
logical_channel_address = 0
logical_channel_address = 8
logical_channel_address = 4
Receiver Channel 0
ALTGX Instance 2
ALTGX Instance 3
Receiver Channel 2 to 4
Receiver Channel 1
ALTGX Instance 1
AEQ Hardware
AEQ Hardware
AEQ Hardware
Stratix IV Device Handbook Volume 2: Transceivers
rx_datain[0]
rx_datain[2]
rx_datain[1]
5–75

Related parts for EP4SE530H40I3