Preliminary Data Sheet
May 2001
11 M13/M23 MUX/DeMUX Registers
Table 214. M13_DELTA1, Delta (RO)
Agere Systems Inc.
Address
0x10004 15:8
Bit
7
6
5
4
3
2
1
0
M13_DS3_IDLEPAT_DETD This delta bit is set if M13_DS3_IDLEPAT_DET
M13_DS3_AISPAT_DETD This delta bit is set if M13_DS3_AISPAT_DET
M13_DS3_CBZ_DETD
M13_DS3_RAI_DETD
M13_DS3_C1_DETD
M13_RDL_IDLED
M13_DS3_OOFD
M13_DS3_LOFD
Name
Reserved.
This delta bit is set if M13_RDL_IDLE
changes state. It can be programmed to be either clear
on read (COR) or clear on write (COW), and it is not set
to 1 again until another state transition occurs.
This delta bit is set if M13_DS3_LOF
changes state. It can be programmed to be either clear
on read (COR) or clear on write (COW), and it is not set
to 1 again until another state transition occurs.
This delta bit is set if M13_DS3_OOF
changes state. It can be programmed to be either clear
on read (COR) or clear on write (COW), and it is not set
to 1 again until another state transition occurs.
This delta bit is set if M13_DS3_C1_DET
changes state. It is cleared when read, and it is not set to
1 again until another state transition occurs.
This delta bit is set if M13_DS3_RAI_DET
changes state. It can be programmed to be either clear
on read (COR) or clear on write (COW), and it is not set
to 1 again until another state transition occurs.
(Table
either clear on read (COR) or clear on write (COW), and it
is not set to 1 again until another state transition occurs.
(Table
either clear on read (COR) or clear on write (COW), and it
is not set to 1 again until another state transition occurs.
This delta bit is set if M13_DS3_CBZ_DET
changes state. It can be programmed to be either clear
on read (COR) or clear on write (COW), and it is not set
to 1 again until another state transition occurs.
(continued)
224) changes state. It can be programmed to be
224) changes state. It can be programmed to be
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1
Function
TMXF28155/51 Super Mapper
(Table
(Table
(Table
(Table
(Table
(Table
224)
224)
224)
224)
224)
224)
Default
Reset
0x00
0
0
0
0
0
0
0
0
199