PEB22554 SIEMENS [Siemens Semiconductor Group], PEB22554 Datasheet - Page 360

no-image

PEB22554

Manufacturer Part Number
PEB22554
Description
ICs for Communications
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
PEB22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
PEB22554HT V1.3
Quantity:
1 078
Part Number:
PEB22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
PEB22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
PEB22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
MFAR…
LMFA…
AIS…
LOS…
RAR…
RA…
Interrupt Status Register 3 (Read)
ISR3
All bits are reset when ISR3 is read.
If bit GCR.VIS is set to ‘1’, interrupt statuses in ISR3 may be flagged although they are
masked via register IMR3. However, these masked interrupt statuses neither generate a
signal on INT, nor are visible in register GIS.
Semiconductor Group
7
ES
Multiframe Alignment Recovery
Set when the framer has reached multiframe alignment in F12 or F72
format. With the negative transition of bit FRS0.LMFA this bit will be
set. It will be set during alarm simulation.
Loss of Multiframe Alignment
Set when the framer has lost the multiframe alignment in F12 or F72
format. With the positive transition of bit FRS0.LMFA this bit will be
set. It will be set during alarm simulation.
Alarm Indication Signal (Blue Alarm)
This bit is set when an alarm indication signal is detected and bit
FRS0.AIS is set. If GCR.SCI is set high this interrupt status bit will be
activated with every change of state of FRS0.AIS.
It will be set during alarm simulation.
Loss of Signal (Red Alarm)
This bit is set when a loss of signal alarm is detected in the received
data stream and FRS0.LOS is set. If GCR.SCI is set high this interrupt
status bit will be activated with every change of state of FRS0.LOS.
It will be set during alarm simulation.
Remote Alarm Recovery
Set if a remote alarm (yellow alarm) is cleared and bit FRS0.RRA is
reset. It is set also after alarm simulation is finished and no remote
alarm is detected.
Remote Alarm
A remote alarm (yellow alarm) is detected. Set with the rising edge of
bit FRS0.RRA. It will be set during alarm simulation.
SEC
360
LLBSC
Operational Description T1 / J1
RSN
0
RSP
PEB 22554
(x6B)
09.98

Related parts for PEB22554