PEB22554 SIEMENS [Siemens Semiconductor Group], PEB22554 Datasheet - Page 362

no-image

PEB22554

Manufacturer Part Number
PEB22554
Description
ICs for Communications
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
PEB22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
PEB22554HT V1.3
Quantity:
1 078
Part Number:
PEB22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
PEB22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
PEB22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Interrupt Status Register 4(Read)
ISR4
All bits are reset when ISR4 is read.
If bit GCR.VIS is set to ‘1’, interrupt statuses in ISR4 may be flagged although they are
masked via register IMR4. However, these masked interrupt statuses neither generate a
signal on INT, nor are visible in register GIS.
XSP…
XSN…
Semiconductor Group
7
XSP
Transmit Slip Positive
The frequency of the transmit clock is less than the frequency of the
transmit system interface working clock based on 1.544 MHz. A frame
will be repeated. After a slip has performed writing of register XC1 is
not necessary.
Transmit Slip Negative
The frequency of the transmit clock is greater than the frequency of
the transmit system interface working clock based on 1.544 MHz. A
frame will be skipped. After a slip has performed writing of register
XC1 is not necessary.
XSN
362
Operational Description T1 / J1
0
PEB 22554