EP4SGX530HH35C2N Altera, EP4SGX530HH35C2N Datasheet - Page 727

IC STRATIX IV FPGA 530K 1152HBGA

EP4SGX530HH35C2N

Manufacturer Part Number
EP4SGX530HH35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX530HH35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
564
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Family Name
Stratix® IV
Number Of Logic Blocks/elements
531200
# Registers
424960
# I/os (max)
560
Process Technology
40nm
Operating Supply Voltage (typ)
900mV
Logic Cells
531200
Ram Bits
28033024
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FCHBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX530HH35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX530HH35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAD
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAE
Manufacturer:
ALTERA
0
Chapter 2: Stratix IV Transceiver Clocking
FPGA Fabric-Transceiver Interface Clocking
© March 2010 Altera Corporation
1
Non-Bonded Channel Configuration Without Rate Matcher
In non-bonded channel configuration without rate matcher, the Quartus II software
cannot determine if the incoming serial data in all channels have a 0 PPM frequency
difference. The Quartus II software automatically drives the read port of the receiver
phase compensation FIFO in each channel with the recovered clock driven on the
rx_clkout port of that channel. Use the rx_clkout signal from each channel to
latch its receiver data and status signals in the FPGA fabric.
This configuration uses one FPGA global, regional clock, or both, resource per
channel for the rx_clkout signal.
Stratix IV Device Handbook Volume 2
2–63