Specifications of RCLXT16706FE

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Not Compliant
Intel IXF6048 — 51/155/622/2488 Mbit/s SONET/SDH Cell/Packet Interface
38
Table 4.
Pin Description (Sheet 24 of 66)
TSOHCK_0
TSOHCK_1
TSOHCK_2
TSOHCK_3
TSAL_0
TSAL_1
TSAL_2
TSAL_3
TSALFR_0
TSALFR_1
TSALFR_2
TSALFR_3
TSALCK_0
TSALCK_1
TSALCK_2
TSALCK_3
RPOH_0
RPOH_1
RPOH_2
RPOH_3
RPOHFR_0
RPOHFR_1
RPOHFR_2
RPOHFR_3
RPOHCK_0
RPOHCK_1
RPOHCK_2
RPOHCK_3
RPAL_0
RPAL_1
RPAL_2
RPAL_3
NOTE: See notes 1, 2, and
Pin Name
AA3
AA2
E26
A29
B28
D27
F26
E27
C28
C29
C30
C31
D28
D29
D26
A28
C27
F24
Pin
W5
R3
R4
R6
R5
U2
U1
U3
Y4
T4
T3
V3
T6
T5
LVTTL
Output
4 mA
LVTTL
Input
LVTTL
Bidir
4 mA
LVTTL
Bidir
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
Type
3
at the end of the table.
Transmit SOH Insertion Clock. TSOHCK_i (i = 0, 1, 2, 3) is a 20.736
MHz (Quad OC-12c), 5.184 MHz (Quad OC-3c), or 1.728 MHz (Quad
OC-1) timing reference signal used to clock in the TSOH_i data on
channel #i.
Transmit Section Alarm Bus. TSAL_i (i = 0, 1, 2, 3) allows the insertion
of the remote defect indication (MS-RDI and MS-REI) and/or the
insertion of the APS bytes K1 and K2 into the transmit SOH on channel
#i.
TSAL_i (i = 0, 1, 2, 3) is clocked in by TSALCK_i.
Transmit Section Alarm Pulse. TSALFR_i (i = 0, 1, 2, 3) is an 8-KHz
pulse indicating the expected position of RDI at the TSAL_i input on
channel #i. The TSALFR_i pulse (i = 0, 1, 2, 3) is repeated every 72
clock cycles of TSALCK_i. TsalBusCnfg (register T_SC_MSOH)
configures the transmit section alarm bus as a codirectional or a
contradirectional interface:
TSALFR_i (i = 0, 1, 2, 3) is clocked out by TSALCK_i.
Transmit Section Alarm Clock. TSALCK_i (i = 0, 1, 2, 3) is a 576-KHz
timing reference signal used to clock in the TSAL_i input on channel #i.
TsalBusCnfg (register T_SC_MSOH) configures the transmit section
alarm bus as a codirectional or a contradirectional interface:
Receive POH Extraction Bus. RPOH_i (i = 0, 1, 2, 3) outputs the POH
bytes extracted from the incoming SONET/SDH frames on channel #i.
RPOH_i (i = 0, 1, 2, 3) is clocked out by RPOHCK_i.
Receive POH Extraction Frame Pulse. RPOHFR_i (i = 0, 1, 2, 3) is an
8-KHz pulse indicating the start of the POH (J1 MSB position) on
RPOH_i.
RPOHFR_i (i = 0, 1, 2, 3) is clocked out by RPOHCK_i.
Receive POH Extraction Clock. RPOHCK_i (i = 0, 1, 2, 3) is a 576-KHz
timing reference signal used to clock out the RPOH_i data on channel #i.
Receive Path Alarm Bus. RPAL_i (i = 0, 1, 2, 3) outputs the receive
side path alarms, detected path errors, the filtered receive signal label,
and the generated remote defects on channel #i. The position of the
generated “server defect” bit at the RPAL_i output (i = 0, 1, 2, 3) is
indicated by the 8-KHz pulse RPOHFR_i.
RPAL_i (i = 0, 1, 2, 3) is clocked out by RPOHCK_i.
• When TsalBusCnfg = '0', TSALFR_i (i = 0, 1, 2, 3) is configured as
• When TsalBusCnfg = '1', TSALFR_i (i = 0, 1, 2, 3) is configured as
• When TsalBusCnfg = '0', TSALCK_i (i = 0, 1, 2, 3) is configured as
• When TsalBusCnfg = '1', TSALCK_i (i = 0, 1, 2, 3) is configured as
an output pin.
an input pin.
an output pin.
an input pin.
Description