D12363VTE33 Renesas Electronics America, D12363VTE33 Datasheet - Page 144

MCU 3V 0K 120-TQFP

D12363VTE33

Manufacturer Part Number
D12363VTE33
Description
MCU 3V 0K 120-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of D12363VTE33

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
84
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
120-TQFP, 120-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Other names
HD6412363VTE33
HD6412363VTE33

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12363VTE33V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 4 Exception Handling
Consequently, on-chip peripheral module registers cannot be read from or written to. Register
reading and writing is enabled when module stop mode is exited.
4.4
Traces are enabled in interrupt control mode 2. Trace mode is not activated in interrupt control
mode 0, irrespective of the state of the T bit. For details on interrupt control modes, see section 5,
Interrupt Controller.
If the T bit in EXR is set to 1, trace mode is activated. In trace mode, a trace exception occurs on
completion of each instruction. Trace mode is not affected by interrupt masking. Table 4.3 shows
the state of CCR and EXR after execution of trace exception handling. Trace mode is canceled by
clearing the T bit in EXR to 0. The T bit saved on the stack retains its value of 1, and when control
is returned from the trace exception handling routine by the RTE instruction, trace mode resumes.
Trace exception handling is not carried out after execution of the RTE instruction.
Interrupts are accepted even within the trace exception handling routine.
Table 4.3
Interrupt Control Mode
0
2
Legend:
1:
0:
—: Retains value prior to execution.
4.5
Interrupts are controlled by the interrupt controller. The interrupt controller has two interrupt
control modes and can assign interrupts other than NMI to eight priority/mask levels to enable
multiplexed interrupt control. The source to start interrupt exception handling and the vector
address differ depending on the product. For details, refer to section 5, Interrupt Controller.
The interrupt exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
Rev.6.00 Mar. 18, 2009 Page 84 of 980
REJ09B0050-0600
(EXR) are saved in the stack.
Set to 1
Cleared to 0
Traces
Interrupts
Status of CCR and EXR after Trace Exception Handling
CCR
I
Trace exception handling cannot be used.
1
UI
EXR
I2 to I0
0
T

Related parts for D12363VTE33