D12363VTE33 Renesas Electronics America, D12363VTE33 Datasheet - Page 668

MCU 3V 0K 120-TQFP

D12363VTE33

Manufacturer Part Number
D12363VTE33
Description
MCU 3V 0K 120-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of D12363VTE33

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
84
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
120-TQFP, 120-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Other names
HD6412363VTE33
HD6412363VTE33

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12363VTE33V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 14 Serial Communication Interface (SCI, IrDA)
14.7.5
Before transmitting and receiving data, initialize the SCI as described below. Initialization is also
necessary when switching from transmit mode to receive mode, or vice versa.
1. Clear the TE and RE bits in SCR to 0.
2. Clear the error flags ERS, PER, and ORER in SSR to 0.
3. Set the GM, BLK, O/E, BCP1, BCP0, CKS1, and CKS0 bits in SMR. Set the PE bit to 1.
4. Set the SMIF, SDIR, and SINV bits in SCMR.
5. Set the value corresponding to the bit rate in BRR.
6. Set the CKE0 and CKE1 bits in SCR. Clear the TIE, RIE, TE, RE, MPIE, and TEIE bits to 0.
7. Wait at least one bit interval, then set the TIE, RIE, TE, and RE bits in SCR. Do not set the TE
To switch from receive mode to transmit mode, after checking that the SCI has finished reception,
initialize the SCI, and clear RE to 0 and set TE to 1. Whether SCI has finished reception can be
checked with the RDRF, PER, or ORER flag. To switch from transmit mode to receive mode,
after checking that the SCI has finished transmission, initialize the SCI, and clear TE to 0 and set
RE to 1. Whether SCI has finished transmission can be checked with the TEND flag.
14.7.6
As data transmission in Smart Card interface mode involves error signal sampling and
retransmission processing, the operations are different from those in normal serial communication
interface mode (except for block transfer mode). Figure 14.26 illustrates the retransfer operation
when the SCI is in transmit mode.
1. If an error signal is sampled from the receiving end after transmission of one frame is
2. The TEND bit in SSR is not set for a frame for which an error signal is received. Data is
3. If an error signal is not sent back from the receiving end, the ERS bit in SSR is not set.
Rev.6.00 Mar. 18, 2009 Page 608 of 980
REJ09B0050-0600
When the SMIF bit is set to 1, the TxD and RxD pins are both switched from ports to SCI pins,
and are placed in the high-impedance state.
If the CKE0 bit is set to 1, the clock is output from the SCK pin.
bit and RE bit at the same time, except for self-diagnosis.
completed, the ERS bit in SSR is set to 1. If the RIE bit in SCR is set at this time, an ERI
interrupt request is generated. The ERS bit in SSR should be cleared to 0 before the next
parity bit is sampled.
retransferred from TDR to TSR, and retransmitted automatically.
Initialization
Data Transmission (Except for Block Transfer Mode)