D12363VTE33 Renesas Electronics America, D12363VTE33 Datasheet - Page 653

MCU 3V 0K 120-TQFP

D12363VTE33

Manufacturer Part Number
D12363VTE33
Description
MCU 3V 0K 120-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of D12363VTE33

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
84
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
120-TQFP, 120-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Other names
HD6412363VTE33
HD6412363VTE33

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12363VTE33V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
No
No
No
Figure 14.13 Sample Multiprocessor Serial Reception Flowchart (1)
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Set MPIE bit in SCR to 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
FER ∨ ORER = 1?
FER ∨ ORER = 1?
All data received?
Start of reception
This station's ID?
Initialization
RDRF = 1?
RDRF = 1?
<End>
Yes
Yes
Yes
Yes
No
No
Section 14 Serial Communication Interface (SCI, IrDA)
Yes
No
Yes
[4]
[3]
[1]
[2]
Error handling
(Continued on
next page)
[5]
Rev.6.00 Mar. 18, 2009 Page 593 of 980
[1]
[2]
[3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station’s ID.
If the data is not this station’s ID,
set the MPIE bit to 1 again, and
clear the RDRF flag to 0.
If the data is this station’s ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error handling and break
detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
handling, ensure that the ORER
and FER flags are both cleared
to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.
REJ09B0050-0600