Reset
The FALC54 is forced to the reset state if a high signal is input at port RES for a minimum
period of 20 s. During RESET, all output stages except CLK16M, CLK12M, CLK8M,
CLKX, FSC, XCLK and RCLK are tri-stated, all internal flip-flops are reset and most of
the control registers are initialized with default values.
After Reset bit FMR1.PMOD has to be set high and the device needs up to 20 sec to
settle up to the internal clocking. After FMR1.PMOD has been set the configuration
shown in table 24 is initialized.
Table 24
Configuration if Initialized after RESET
Register
FMR0
FMR1
FMR2
LOOP
FMR4
FMR5
XC0
XC1
RC0
RC1
IDLE
ICB 1
CCB 1
LIM0
LIM1
PCD
PCR
XPM2-0
IMR1-4
Semiconductor Group
Operational Description T1
3
3
Initiated
Value
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
9c
FF
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
,03
H
,00
H
Meaning
NRZ Coding, No alarm simulation.
PCM 24 mode, 4 Mbit/s system interface mode, no AIS
transmission to remote end or system interface, Payload
Loop off
Channel loop back are disabled.
Remote alarm indication towards remote end disabled.
LFA condition: 2 out of 4 framing bits,
Non-auto-synchronization mode, F12 multiframing,
internal Bit Robbing Access disabled
The transmit clock-slot offset is cleared.
The transmit time-slot Offset is cleared.
The receive clock slot offset is cleared.
The receive time-slot offset is cleared.
Idle channel code is cleared.
Normal operation (no “Idle Channels” selected).
Normal operation (no clear channel operation).
Slave Mode, Local Loop off, frequency on pin CLKX:
2.048 MHz, no LOS indication on pin RCLK
Analog interface selected, Remote Loop off
Pulse Count for LOS Detection cleared
Pulse Count for LOS Recovery cleared
Transmit Pulse Mask
All interrupts are disabled