PEB2255H-V13 Infineon Technologies, PEB2255H-V13 Datasheet - Page 183

IC INTERFACE LINE 80-MQFP

PEB2255H-V13

Manufacturer Part Number
PEB2255H-V13
Description
IC INTERFACE LINE 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB2255H-V13

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
80-SQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2255H-V13
PEB2255H-V13IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2255H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
9.2
Transmit FIFO (Write)
Command Register (Write)
Value after RESET: 00
RMC…
RRES…
XREP…
Data Sheet
XFIFO
CMDR
RMC
XF7
Detailed Description of E1 Control Registers
7
7
Writing data to XFIFO can be done in 8-bit (byte) or 16-bit (word)
access. The LSB is transmitted first.
Up to 32 bytes/16 words of transmit data can be written to the XFIFO
following a XPR (or ALLS) interrupt.
Receive Message Complete
Confirmation from CPU to FALC
block has been fetched following a RPF or RME interrupt, thus the
occupied space in the RFIFO can be released.
Receiver Reset
The receive line interface except the clock and data recovery unit
(DPLL), the DCR-R circuitry, the receive framer, the one second timer
and the receive signaling controller are reset. However the contents
of the control registers is not deleted. RRES has to be given every
time after a configuration change.
Transmission Repeat
If XREP is set together with XTF (write 24
repeatedly transmits the contents of the XFIFO (1 … 32 bytes)
without HDLC framing fully transparently, i.e. without FLAG,CRC.
The cyclic transmission is stopped with a SRES command or by
resetting XREP.
Note: During cyclic transmission the XREP-bit has to be set with
RRES
H
every write operation to CMDR.
XREP
XRES
183
XHF
®
-LH that the current frame or data
XTF
H
to CMDR), the FALC
XME
FALC-LH V1.3
SRES
XF0
E1 Registers
0
0
PEB 2255
(00/01)
2000-07
(02)
®
-LH