PEB2255H-V13 Infineon Technologies, PEB2255H-V13 Datasheet - Page 323

IC INTERFACE LINE 80-MQFP

PEB2255H-V13

Manufacturer Part Number
PEB2255H-V13
Description
IC INTERFACE LINE 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB2255H-V13

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
80-SQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2255H-V13
PEB2255H-V13IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2255H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
BOM…
Receive Signaling Status Register (Read)
RSIS relates to the last received HDLC or BOM frame; it is copied into RFIFO when end-
of-frame is recognized (last byte of each stored frame).
VFR…
RDO…
CRC16…
Data Sheet
RSIS
VFR
7
Bit Oriented Message
Significant only in ESF frame format and auto switching mode is
enabled.
0…
1…
Valid Frame
Determines whether a valid frame has been received.
– a frame which is not an integer number of 8 bits (n
– a frame which is too short taking into account the operation mode
Note:Shorter frames are not reported.
Receive Data Overflow
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR1.RDO/IMR1.RDO).
CRC16 Compare/Check
0
1
1
0
An invalid frame is either
RDO
(e.g. 25 bits), or
selected via MODE (MDS2...0) and the selection of receive CRC
ON/OFF (CCR3.RCRC) as follows:
• MDS2...0 = 011 (16 bit Address),
• MDS2...0 = 010 (8 bit Address),
RCRC = 0 : 4 bytes; RCRC = 1 : 3-4 bytes
RCRC = 0 : 3 bytes; RCRC = 1 : 2-3 bytes
HDLC mode
BOM mode
valid HDLC frame
invalid HDLC frame
CRC check failed; received frame contains errors.
CRC check o.k.; received frame is error-free.
CRC16
RAB
323
HA1
HA0
HFR
FALC-LH V1.3
T1/J1 Registers
8 bits) in length
LA
0
PEB 2255
2000-07
(65)