D12332VFC25 Renesas Electronics America, D12332VFC25 Datasheet - Page 665

MCU 3V 0K 144-QFP

D12332VFC25

Manufacturer Part Number
D12332VFC25
Description
MCU 3V 0K 144-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of D12332VFC25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
106
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 4x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Other names
HD6412332VFC25
HD6412332VFC25

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12332VFC25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Serial data reception (asynchronous mode): Figure 14.7 shows a sample flowchart for serial
reception.
The following procedure should be used for serial data reception.
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1?
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read ORER, PER, and
All data received?
FER flags in SSR
Start of reception
Figure 14.7 Sample Serial Reception Flowchart
Initialization
RDRF = 1?
<End>
Yes
Yes
No
(Continued on next page)
Error handling
Yes
[1]
[2]
[4]
[5]
[3]
Rev.4.00 Sep. 07, 2007 Page 633 of 1210
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DMAC or DTC is
activated by an RXI interrupt and
the RDR value is read.
Receive error handling and
REJ09B0245-0400

Related parts for D12332VFC25