EP2AGX95EF29C4N Altera, EP2AGX95EF29C4N Datasheet - Page 360

no-image

EP2AGX95EF29C4N

Manufacturer Part Number
EP2AGX95EF29C4N
Description
IC ARRIA II GX FPGA 95K 780FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX95EF29C4N

Number Of Logic Elements/cells
89178
Number Of Labs/clbs
3747
Total Ram Bits
6679
Number Of I /o
372
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
93674
# I/os (max)
372
Frequency (max)
500MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
93674
Ram Bits
7025459.2
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX95EF29C4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX95EF29C4N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX95EF29C4N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
10–10
Recovering From CRC Errors
Document Revision History
Table 10–9. Document Revision History
Arria II Device Handbook Volume 1: Device Interfaces and Integration
December 2010
July 2010
November 2009
February 2009
Date
The system that the Arria II device resides in must control device reconfiguration.
After detecting an error on the CRC_ERROR pin, strobing the nCONFIG signal low directs
the system to perform the reconfiguration at a time when it is safe for the system to
reconfigure the device.
When the data bit is rewritten with the correct value by reconfiguring the device, the
device functions correctly.
While soft errors are uncommon in Altera
applications require a design to account for these errors.
Table 10–9
Version
4.0
3.0
2.0
1.0
lists the revision history for this chapter.
Updated for Arria II GX v10.0 release:
Updated for Arria II GX v9.1 release:
Initial release.
Updated for the Quartus II software version 10.1 release.
Added Arria II GZ devices information.
Minor text edits.
Updated Table 10–3, Table 10–6, Table 10–7, and Table 10–8.
Updated Table 10–7 and Table 10–8.
Minor text edits.
®
devices, certain high-reliability
Changes
Chapter 10: SEU Mitigation in Arria II Devices
December 2010 Altera Corporation
Recovering From CRC Errors

Related parts for EP2AGX95EF29C4N