E62655RUSB Renesas Electronics America, E62655RUSB Datasheet - Page 94

no-image

E62655RUSB

Manufacturer Part Number
E62655RUSB
Description
EMULATOR BASE H8S/2655R W/USB
Manufacturer
Renesas Electronics America
Type
Microcontrollerr
Datasheet

Specifications of E62655RUSB

Contents
E6000 Emulator Unit and 4 Logic Probes
For Use With/related Products
H8S/2655R
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Section 2 CPU
(2) Reset Exception Handling
After the RES pin has gone low and the reset state has been entered, when RES goes high again,
reset exception handling starts. When reset exception handling starts the CPU fetches a start
address (vector) from the exception vector table and starts program execution from that address.
All interrupts, including NMI, are disabled during reset exception handling and after it ends.
(3) Traces
Traces are enabled only in interrupt control modes 2 and 3. Trace mode is entered when the T bit
of EXR is set to 1. When trace mode is established, trace exception handling starts at the end of
each instruction.
At the end of a trace exception-handling sequence, the T bit of EXR is cleared to 0 and trace mode
is cleared. Interrupt masks are not affected.
The T bit saved on the stack retains its value of 1, and when the RTE instruction is executed to
return from the trace exception-handling routine, trace mode is entered again. Trace exception-
handling is not executed at the end of the RTE instruction.
Trace mode is not entered in interrupt control modes 0 and 1, regardless of the state of the T bit.
(4) Interrupt Exception Handling and Trap Instruction Exception Handling
When interrupt or trap-instruction exception handling begins, the CPU references the stack pointer
(ER7) and pushes the program counter and other control registers onto the stack. Next, the CPU
alters the settings of the interrupt mask bits in the control registers. Then the CPU fetches a start
address (vector) from the exception vector table and program execution starts from that start
address.
Figure 2.16 shows the stack after exception handling ends.
Rev. 5.00 Sep 14, 2006 page 64 of 1060