TMP91xy16FG Toshiba, TMP91xy16FG Datasheet - Page 170

no-image

TMP91xy16FG

Manufacturer Part Number
TMP91xy16FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP91xy16FG

Package
LQFP100
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
Ramless
Architecture
16-bit CISC
Usb/spi Channels
-
Uart/sio Channels
1
I2c/sio Bus Channels
-
(s)dram Controller
1
Adc 10-bit Channel
-
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
-
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
31
Power Supply Voltage(v)
2.7 to 3.6
3.11.2
Note1: If it is used disable control, set the disable code (B1H) to WDCR after write the clear code (4EH) once. (Please
Note2: If it is changed Watchdog timer setting, change setting after set to disable condition once.
Control Registers
(1) Watchdog timer mode register (WDMOD)
(2) Watchdog timer control register (WDCR)
The watchdog timer WDT is controlled by two control registers WDMOD and WDCR.
refer to setting example.)
0 and then writing the disable code (B1H) to the WDCR register.
a.
b.
c.
This register is used to disable and clear the binary counter for the watchdog timer.
Disable control the watchdog timer can be disabled by clearing WDMOD<WDTE> to
WDMOD
WDCR
WDCR
Enable control
Watchdog timer clear control
Setting the detection time for the watchdog timer in <WDTP1:0>
when
WDMOD<WDTP1:0> = 00.
Watchdog timer enable/disable control register <WDTE>
disable code (B1H) to the watchdog timer control register WDCR. This makes it
difficult for the watchdog timer to be disabled by runaway.
the enabled state merely by setting <WDTE> to 1.
Watchdog timer out reset connection <RESCR>
RESET terminal internally. Since WDMOD<RESCR>is initialized to 0 on reset, a
reset by the watchdog timer will not be performed.
(4EH) to the WDCR register.
This 2-bit register is used for setting the watchdog timer interrupt time used
The detection times for WDT are shown in Figure 3.11.4.
After Reset, WDMOD<WDTE> is initialized to 1, enabling the watchdog timer.
To disable the watchdog timer, it is necessary to set this bit to 0 and to write the
However, it is possible to return the watchdog timer from the disabled state to
This register is used to connect the output of the watchdog timer with the
Set WDMOD<WDTE> to 1.
To clear the binary counter and cause counting to resume, write the clear code
detecting
← 0 − − − − − − −
← 1 0 1 1 0 0 0 1
← 0 1 0 0 1 1 1 0
runaway.
91C016-168
After
Clear WDMOD<WDTE> to 0.
Write the disable code (B1H).
Write the clear code (4EH).
reset,
this
register
is
initialized
TMP91C016
2008-02-20
to

Related parts for TMP91xy16FG