Specifications of HD64F2623FA20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
53
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2623FA20J
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2623FA20J
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F2623FA20J
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64F2623FA20JV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Serial Data Reception (Except Block Transfer Mode): Data reception in Smart Card mode uses
the same processing procedure as for the normal SCI. Figure 14.7 shows an example of the
transmission processing flow.
[1] Perform Smart Card interface mode initialization as described above in Initialization.
[2] Check that the ORER flag and PER flag in SSR are cleared to 0. If either is set, perform the
[3] Repeat steps [2] and [3] until it can be confirmed that the RDRF flag is set to 1.
[4] Read the receive data from RDR.
[5] When receiving data continuously, clear the RDRF flag to 0 and go back to step [2].
[6] To end reception, clear the RE bit to 0.
appropriate receive error processing, then clear both the ORER and the PER flag to 0.
No
No
Figure 14.7 Example of Reception Processing Flow
RDRF flag in SSR to 0
Read RDR and clear
All data received?
Clear RE bit to 0
ORER = 0 and
Start reception
Initialization
RDRF = 1?
PER = 0
Start
Yes
Yes
Yes
No
Rev. 5.00 Jan 10, 2006 page 513 of 1042
Error processing
Section 14 Smart Card Interface
REJ09B0275-0500