UPD78F1506GF-GAT-AX Renesas Electronics America, UPD78F1506GF-GAT-AX Datasheet - Page 356

no-image

UPD78F1506GF-GAT-AX

Manufacturer Part Number
UPD78F1506GF-GAT-AX
Description
MCU 16BIT 78K0R/LX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Lx3r
Datasheet

Specifications of UPD78F1506GF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LCD, LVD, POR, PWM, WDT
Number Of I /o
78
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0R/Lx3
R01UH0004EJ0401 Rev.4.01
Jul 2, 2010
Address: FFF9DH
RTCC0
Symbol
Note RCLOE0 and RCLOE2 must not be enabled at the same time.
Caution If RCLOE0 and RCLOE1 are changed when RTCE = 1, the last waveform of the 32.768 kHz and 1
Remark ×: don’t care
• To change the value of AMPM, set RWAIT (bit 0 of RTCC1) to 1, and re-set the hour count register (HOUR).
• Table 7-2 shows the displayed time digits that are displayed.
When changing the values of CT2 to CT0 while the counter operates (RTCE = 1), rewrite the values of CT2 to CT0
after disabling interrupt servicing INTRTC by using the interrupt mask flag register. Furthermore, after rewriting the
values of CT2 to CT0, enable interrupt servicing after clearing the RIFG and RTCIF flags.
RCLOE0
RCLOE1
AMPM
RTCE
RTCE
CT2
Hz output signals may become short.
<7>
0
1
0
1
0
1
0
1
0
0
0
0
1
1
1
After reset: 00H
Note
Figure 7-3. Format of Real-Time Counter Control Register 0 (RTCC0)
Stops counter operation.
Starts counter operation.
Disables output of RTC1HZ pin (1 Hz).
Enables output of RTC1HZ pin (1 Hz).
Disables output of RTCCL pin (32 kHz).
Enables output of RTCCL pin (32 kHz).
12-hour system (a.m. and p.m. are displayed.)
24-hour system
CT1
0
0
1
1
0
0
1
6
0
R/W
RCLOE1
CT0
<5>
0
1
0
1
0
1
×
Does not use constant-period interrupt function.
Once per 0.5 s (synchronized with second count up)
Once per 1 s (same time as second count up)
Once per 1 m (second 00 of every minute)
Once per 1 hour (minute 00 and second 00 of every hour)
Once per 1 day (hour 00, minute 00, and second 00 of every day)
Once per 1 month (Day 1, hour 00 a.m., minute 00, and second 00 of
every month)
RCLOE0
Real-time counter operation control
<4>
Selection of 12-/24-hour system
RTC1HZ pin output control
RTCCL pin output control
Constant-period interrupt (INTRTC) selection
AMPM
3
CHAPTER 7 REAL-TIME COUNTER
CT2
2
CT1
1
CT0
0
356