SAM9G45 Atmel Corporation, SAM9G45 Datasheet - Page 574

no-image

SAM9G45

Manufacturer Part Number
SAM9G45
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9G45

Flash (kbytes)
0 Kbytes
Pin Count
324
Max. Operating Frequency
400 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
160
Ext Interrupts
160
Usb Transceiver
3
Usb Speed
Hi-Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
2
Uart
5
Lin
4
Ssc
2
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
Yes
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
440
Resistive Touch Screen
Yes
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
NO
External Bus Interface
2
Dram Memory
DDR2/LPDDR, SDRAM/LPSDR
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
0.9 to 1.1
Fpu
No
Mpu / Mmu
No/Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
Figure 33-24. Receiver Time-out Block Diagram
574
SAM9G45
RETTO
Character
Received
STTTO
If STTTO is performed, the counter clock is stopped until a first character is received. The idle
state on RXD before the start of the frame does not provide a time-out. This prevents having to
obtain a periodic interrupt and enables a wait of the end of frame when the idle state on RXD is
detected.
If RETTO is performed, the counter starts counting down immediately from the value TO. This
enables generation of a periodic interrupt so that a user time-out can be handled, for example
when no key is pressed on a keyboard.
Figure 33-24
Table 33-11
Table 33-11. Maximum Time-out Period
• Obtain an interrupt while no character is received. This is performed by writing US_CR with
on RXD before a new character is received will not provide a time-out. This prevents having
to handle an interrupt before a character is received and allows waiting for the next idle state
on RXD after a frame is received.
the RETTO (Reload and Start Time-out) bit at 1. If RETTO is performed, the counter starts
counting down immediately from the value TO. This enables generation of a periodic interrupt
so that a user time-out can be handled, for example when no key is pressed on a keyboard.
1
D
Baud Rate
gives the maximum time-out period for some standard baud rates.
bit/sec
14400
19200
28800
33400
1 200
2 400
4 800
9 600
shows the block diagram of the Receiver Time-out feature.
Clear
600
Q
Baud Rate
Clock
Clock
16-bit Time-out
Counter
TO
Bit Time
1 667
Load
833
417
208
104
μs
69
52
35
30
16-bit
Value
0
=
TIMEOUT
Time-out
109 225
54 613
27 306
13 653
6 827
4 551
3 413
2 276
1 962
6438G–ATARM–19-Apr-11
ms