SAM9G45 Atmel Corporation, SAM9G45 Datasheet - Page 592

no-image

SAM9G45

Manufacturer Part Number
SAM9G45
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9G45

Flash (kbytes)
0 Kbytes
Pin Count
324
Max. Operating Frequency
400 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
160
Ext Interrupts
160
Usb Transceiver
3
Usb Speed
Hi-Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
2
Uart
5
Lin
4
Ssc
2
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
Yes
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
440
Resistive Touch Screen
Yes
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
NO
External Bus Interface
2
Dram Memory
DDR2/LPDDR, SDRAM/LPSDR
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
0.9 to 1.1
Fpu
No
Mpu / Mmu
No/Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
33.7.8.7
Figure 33-42. Synch Field
Figure 33-43. Slave Node Synchronization
592
Fractional Part (FP)
Clcok Divider (CD)
Synchro Counter
US_BRGR
US_BRGR
Baud Rate
LINIDRX
SAM9G45
Clock
RXD
Slave Node Synchronization
The synchronization is done only in Slave node configuration. The procedure is based on time
measurement between falling edges of the Synch Field. The falling edges are available in dis-
tances of 2, 4, 6 and 8 bit times.
The time measurement is made by a 19-bit counter clocked by the sampling clock (see
33.7.1).
When the start bit of the Synch Field is detected the counter is reset. Then during the next 8
Tbits of the Synch Field, the counter is incremented. At the end of these 8 Tbits, the counter is
stopped. At this moment, the 16 most significant bits of the counter (value divided by 8) gives the
new clock divider (CD) and the 3 least significant bits of this value (the remainder) gives the new
fractional part (FP).
When the Synch Field has been received, the clock divider (CD) and the fractional part (FP) are
updated in the Baud Rate Generator register (US_BRGR).
The accuracy of the synchronization depends on several parameters:
The following formula is used to compute the deviation of the slave bit rate relative to the master
bit rate after synchronization (F
• The nominal clock frequency (F
• The Baudrate
• The oversampling (Over=0 => 16X or Over=0 => 8X)
13 dominant bits (at 0)
Start
bit
Break Field
2 Tbit
Initial CD
Initial FP
2 Tbit
1 recessive bit
Delimiter
Break
(at 1)
8 Tbit
Synch Field
Reset
SLAVE
2 Tbit
Start
Bit
Nom
is the real slave node clock frequency).
1
) (the theoretical slave node clock frequency)
0
Synch Byte = 0x55
1
2 Tbit
0
1
0
1
0
000_0011_0001_0110_1101
Stop
Bit
Stop
0000_0110_0010_1101
101
bit
Start
Bit
ID0 ID1 ID2 ID3 ID4 ID5 ID6 ID7
6438G–ATARM–19-Apr-11
Stop
Bit
Section