HD6432621 Hitachi, HD6432621 Datasheet - Page 556

no-image

HD6432621

Manufacturer Part Number
HD6432621
Description
(HD64F262x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet
requests, and receive data full interrupt (RXI) requests. The transmit end interrupt (TEI) request is
not used in this mode.
When the TEND flag in SSR is set to 1, a TXI interrupt request is generated.
When the RDRF flag in SSR is set to 1, an RXI interrupt request is generated.
When any of flags ORER, PER, and ERS in SSR is set to 1, an ERI interrupt request is generated.
The relationship between the operating states and interrupt sources is shown in table 14-8.
Note: For block transfer mode, see section 13.4, SCI Interrupts.
Table 14-8 Smart Card Mode Operating States and Interrupt Sources
Operating State
Transmit
Mode
Receive
Mode
Data Transfer Operation by DTC: In smart card mode, as with the normal SCI, transfer can be
carried out using the DTC. In a transmit operation, the TDRE flag is also set to 1 at the same time
as the TEND flag in SSR, and a TXI interrupt is generated. If the TXI request is designated
beforehand as a DTC activation source, the DTC will be activated by the TXI request, and transfer
of the transmit data will be carried out. The TDRE and TEND flags are automatically cleared to 0
when data transfer is performed by the DTC. In the event of an error, the SCI retransmits the same
data automatically. During this period, TEND remains cleared to 0 and the DTC is not activated.
Therefore, the SCI and DTC will automatically transmit the specified number of bytes, including
retransmission in the event of an error. However, the ERS flag is not cleared automatically when
an error occurs, and so the RIE bit should be set to 1 beforehand so that an ERI request will be
generated in the event of an error, and the ERS flag will be cleared.
When performing transfer using the DTC, it is essential to set and enable the DTC before carrying
out SCI setting. For details of the DTC setting procedures, see section 8, Data Transfer Controller
(DTC).
In a receive operation, an RXI interrupt request is generated when the RDRF flag in SSR is set to
1. If the RXI request is designated beforehand as a DTC activation source, the DTC will be
activated by the RXI request, and transfer of the receive data will be carried out. The RDRF flag is
cleared to 0 automatically when data transfer is performed by the DTC. If an error occurs, an error
flag is set but the RDRF flag is not. Consequently, the DTC is not activated, but instead, an ERI
interrupt request is sent to the CPU. Therefore, the error flag should be cleared.
512
Normal
operation
Error
Normal
operation
Error
Flag
TEND
ERS
RDRF
PER, ORER
Enable Bit
TIE
RIE
RIE
RIE
Interrupt Source DTC Activation
TXI
ERI
RXI
ERI
Possible
Not possible
Possible
Not possible