UPD70F3738GF-GAS-AX Renesas Electronics America, UPD70F3738GF-GAS-AX Datasheet - Page 469

no-image

UPD70F3738GF-GAS-AX

Manufacturer Part Number
UPD70F3738GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3738GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3738GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
(7) Minute count register (RC1MIN)
(8) Hour count register (RC1HOUR)
The RC1MIN register is an 8-bit register that takes a value of 0 to 59 (decimal) and indicates the count value of
minutes.
It counts up when the second counter overflows.
When data is written to this register, it is written to a buffer and then to the counter up to 2 clocks (32.768 kHz)
later. Set a decimal value of 00 to 59 to this register in BCD code.
This register can be read or written 8-bit units.
Reset sets this register to 00H.
Caution Setting a value other than 00 to 59 to the RC1MIN register is prohibited.
Remark
The RC1HOUR register is an 8-bit register that takes a value of 0 to 23 or 1 to 12 (decimal) and indicates the
count value of hours.
It counts up when the minute counter overflows.
When data is written to this register, it is written to a buffer and then to the counter up to 2 clocks (32.768 kHz)
later. Set a decimal value of 00 to 23, 01 to 12, or 21 to 32 to this register in BCD code. If a value outside this
range is set, the register value returns to the normal value after 1 period.
This register can be read or written 8-bit units.
Reset sets this register to 12H.
However, the value of this register is 00H if the AMPM bit is set to 1 after reset.
Cautions 1. Bit 5 of the RC1HOUR register indicates a.m. (0) or p.m. (1) if AMPM = 0 (if the 12-hour
Remark
RC1HOUR
RC1MIN
See 11.4.1 Initial settings, 11.4.2 Rewriting each counter during clock operation, and 11.4.3
Reading each counter during clock operation when reading or writing the RC1MIN register.
See 11.4.1 Initial settings, 11.4.2 Rewriting each counter during clock operation, and 11.4.3
Reading each counter during clock operation when reading or writing the RC1HOUR register.
2. Setting a value other than 01 to 12, 21 to 32 (AMPM bit= 0), or 00 to 23 (AMPM bit = 1)
After reset: 00H
After reset: 12H
system is selected).
to the RC1HOUR register is prohibited.
CHAPTER 11 REAL-TIME COUNTER (
0
0
R/W
R/W
0
User’s Manual U18953EJ5V0UD
Address: FFFFFAD3H
Address: FFFFFAD4H
PD70F3792, 70F3793)
467