UPD70F3738GF-GAS-AX Renesas Electronics America, UPD70F3738GF-GAS-AX Datasheet - Page 832

no-image

UPD70F3738GF-GAS-AX

Manufacturer Part Number
UPD70F3738GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3738GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3738GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
830
(4) Regulator protection register (REGPR)
The REGPR register is used to protect the regulator output voltage level control register 0 (REGOVL0) so that
illegal data is not written to REGOVL0. Data cannot be written to the REGOVL0 register unless enabling data
(C9H) is written to the REGPR register. Only two types of data, C9H (enabling data) and 00H (protection data),
can be written to the REGPR register. Writing any other value is prohibited. (If a value other than C9H or 00H
is written to the REGPR register, the written value is set to prohibit a write access to the REGOVL0 register,
but the operation is not guaranteed.)
This register can be read or written only in 8-bit units (accessing it in 1-bit units is prohibited).
Reset sets this register to 00H (protection data status).
• Protection data status: REGPR = 00H
• Enabling data status: REGPR = C9H
In this status, the REGOVL0 register is protected from an illegal write access. In the protection data
status, a value is not written to the REGOVL0 register even if an attempt is made to write it, and the
REGOVL0 register holds the previous value.
Be sure to set REGPR to 00H, except when changing the value of the REGOVL0 register, in order to
avoid unexpected malfunction.
In this status, a write access to the REGOVL0 register is enabled.
• Transition from normal mode → low-voltage STOP mode
• Transition of subclock operation mode → low-voltage subclock operation mode
• Transition of subclock operation mode → low-voltage sub-IDLE mode
See 23.8.1 Setting and operation status.
See 23.6.1 Setting and operation status.
See 23.7.1 Setting and operation status.
REGPR
After reset: 00H
PR7
R/W
PR6
CHAPTER 23 STANDBY FUNCTION
Address: FFFFF331H
User’s Manual U18953EJ5V0UD
PR5
PR4
PR3
PR2
PR1
PR0