peb2255 Infineon Technologies Corporation, peb2255 Datasheet - Page 116

no-image

peb2255

Manufacturer Part Number
peb2255
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
peb22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
peb22554HT V1.3
Quantity:
1 078
Part Number:
peb22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
peb22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
peb22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2255H
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
• a receive slip occurred
5.1.12.3 CAS Bit-robbing (T1/J1, µP access mode)
The signaling information is carried in the LSB of every sixth frame for each time slot.
The signaling controller samples the bit stream on the receive line side. Receive
signaling data is stored in the registers RS1-12.
To relieve the µP load from always reading the complete RS1-12 buffer every 3 ms the
FALC
multiframe to the next.
5.1.12.4 Bit Oriented Messages in ESF-DL Channel (T1/J1)
The FALC
T1.403 specification or according to AT&T TR54016. The HDLC- and Bit Oriented
Message (BOM)-Receiver may be switched ON/OFF independently. If the FALC
used for HDLC formats only, the BOM receiver has to be switched off. If HDLC- and
BOM-receiver has been switched on (MODE.HRAC/BRAC), an automatic switching
between HDLC and BOM mode is enabled. If eight or more consecutive ones are
detected, the BOM mode is entered. Upon detection of a flag in the data stream, the
FALC
assumed (the left most bit is received first): 111111110xxxxxx0
Two different BOM reception modes can be programmed (CCR1.BRM).
5.1.12.5 Data Link Access in F72 Format (T1/J1)
The DL-channel protocol is supported as follows:
- access is done on a multiframe basis via registers RDL1-3,
- the DL bit information from frame 26 to 72 is stored in the Receive FIFO of the signaling
controller.
5.2
The interface to the receive system highway is realized by two data buses, one for the
data RDO and one for the signaling data RSIG. The receive highway is clocked via pin
SCLKR, while the interface to the transmit system highway is independently clocked via
pin SCLKX. The frequency of these working clocks and the data rate for the receive and
transmit system interface is programmable by SIC1.SRSC and SIC1.SXSC. Transmit
and receive clock frequencies have to be the same. Selectable system clock and data
rates and their valid combinations are shown in the table below.
Data Sheet
®
®
-LH notifies the µP via interrupt ISR0.RSC only when signaling changes from one
-LH switches back to HDLC-mode. In BOM-mode, the following byte format is
®
System Interface in T1/J1 Mode
-LH supports the DL-channel protocol for ESF format according to ANSI
116
Functional Description T1/J1
FALC-LH V1.3
PEB 2255
2000-07
®
-LH is