peb2255 Infineon Technologies Corporation, peb2255 Datasheet - Page 295

no-image

peb2255

Manufacturer Part Number
peb2255
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
peb22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
peb22554HT V1.3
Quantity:
1 078
Part Number:
peb22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
peb22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
peb22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2255H
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Pulse Count Recovery (Read/Write)
Value after RESET: 00
PCR7…PCR0… Pulse Count Recovery
Line Interface Mode 2 (Read/Write)
Value after RESET: 00
LBO2...LBO1…
Data Sheet
LIM2
PCR
PCR7
LBO2
7
7
A LOS alarm (red alarm) is cleared if a pulse density is detected in the
received bit stream.The number of pulses M which must occur in the
predefined PCD time interval is programmable via the PCR register
and can be calculated as follows:
M = N+1 ; with 0
The time interval starts with the first detected pulse transition. With
every received pulse a counter is incremented and the actual counter
is compared with the contents of PCR register. If the pulse number is
active. In this case the next detected pulse transition starts a new time
interval. An additional Loss of Signal recovery condition may be
selected by register LIM2.LOS2...1.
In long haul applications LIM0.EQON = 1 a transmit filter can be
optionally placed on the transmit path to attenuate the data on pins
XL1/2. Selecting the transmitter attenuation is possible in steps of 7.5
dB @772kHz which is according to FCC 68 or ANSI T1. 403.
To meet the line build-out defined by ANSI T1.403 registers XPM2...0
should be programmed as follows:
00… 0 dB
01… -7.5 dB --> XPM2...0 = 20
10… -15 dB --> XPM2...0 = 20
11… -22.5 dB --> XPM2...0 = 20
Line Build-Out
LBO1
the PCR value the LOS alarm is reset otherwise the alarm stays
H
H
DJA2
DJA1
N
255.
295
SCF
H
H
, 01
, 02
H
, 01
ELT
H
H
, 8E
, 11
H
, 09
H
H
H
LOS2
FALC-LH V1.3
T1/J1 Registers
PCR0
LOS1
0
0
PEB 2255
2000-07
(37)
(38)