peb2255 Infineon Technologies Corporation, peb2255 Datasheet - Page 157

no-image

peb2255

Manufacturer Part Number
peb2255
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
peb22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
peb22554HT V1.3
Quantity:
1 078
Part Number:
peb22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
peb22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
peb22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2255H
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
PEB 2255
FALC-LH V1.3
Functional Description T1/J1
5.6.6
Alarm Simulation (T1/J1)
Alarm simulation does not affect the normal operation of the device, i.e. all time slots
remain available for transmission. However, possible “real“ alarm conditions are not
reported to the processor or to the remote end when the device is in the alarm simulation
mode.
The alarm simulation is initiated by setting the bit FMR0.SIM. The following alarms are
simulated:
• Loss of Signal (red alarm)
• Alarm Indication Signal AIS (blue alarm)
• Loss of pulse frame
• Remote alarm (yellow alarm) indication
• Receive and transmit slip indication
• Framing error counter
• Code violation counter
• CRC6 error counter
®
Some of the above indications are only simulated if the FALC
-LH is configured in a
mode where the alarm is applicable.
The alarm simulation is controlled by the value of the Alarm Simulation Counter:
FRS2.ESC which is incremented by setting bit: FMR0.SIM.
Clearing of alarm indications:
• Automatically for LOS, remote (yellow) alarm, AIS, and loss of synchronization or
• User controlled for slips by reading the corresponding interrupt status register ISR3 or
• Error counter have been cleared by reading the corresponding counter registers.
Clearing is only possible at defined counter steps of FRS2.ESC. For complete simulation
(FRS2.ESC = 0), eight simulation steps are necessary.
Data Sheet
157
2000-07

Related parts for peb2255