peb2255 Infineon Technologies Corporation, peb2255 Datasheet - Page 162

no-image

peb2255

Manufacturer Part Number
peb2255
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
peb22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
peb22554HT V1.3
Quantity:
1 078
Part Number:
peb22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
peb22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
peb22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2255H
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Table 42
Register
FMR2.ALMF = 1
FMR2.FRS1/0 = 11 In the interworking mode the FALC
Table 43
Register
MODE = 88
CCR1 = 18
IMR0.RME = 0
IMR0.RPF = 0
IMR1.XPR = 0
RTR3.TS16 = 1
TTR3.TS16 = 1
Table 44
Register
XSP.CASEN = 1
IMR0.CASC = 0
Note: After the device initialization a software reset should be executed by setting
Data Sheet
of bits CMDR.XRES/RRES.
H
H
Framer Initialization (E1) (cont’d)
HDLC Controller Initialization (E1)
CAS-CC Initialization (E1)
Function
The receiver initiates a new basic- and multiframing research if
more than 914 CRC4 errors have been detected in one second.
format if no multiframe pattern could be found in a time interval of
400 ms. This is also indicated by a 400 ms interrupt. Additionally
the extended interworking mode (FMR3.EXTIW = 1) will activate
after 400 ms the remote alarm (FMR2.AXRA = 1) and will still
search the multiframing without switching completely to the double
framing. A complete resynchronization in an 8 ms interval is not
initiated.
Function
HDLC Receiver active, no address comparison.
Enable Signaling via TS0...31, Interframe Time Fill with
continuous FLAGs.
Unmask interrupts for HDLC processor requests.
Select TS16 for HDLC data reception and transmission.
Function
Send CAS info stored in the XS1...16 registers.
Enable interrupt with any data change in the RS1...16 registers.
162
®
-LH stays in double framing
Operational Description E1
FALC-LH V1.3
PEB 2255