peb2255 Infineon Technologies Corporation, peb2255 Datasheet - Page 214

no-image

peb2255

Manufacturer Part Number
peb2255
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
peb22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
peb22554HT V1.3
Quantity:
1 078
Part Number:
peb22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
peb22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
peb22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2255H
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
LL…
MAS…
Line Interface Mode 1 (Read/Write)
Value after RESET: 00
EFSC…
RIL2…0…
Note: LIM1.RIL(2:0) must be programmed before LIM0.EQON = 1 is set.
Data Sheet
LIM1
EFSC
7
Local Loop
0…
1…
Master Mode
0…
0…
1…
Receive Input Threshold
Only valid if analog line interface in short haul mode is selected
(LIM0.EQON=0 and LIM1.DRS=0).
Loss of signal is declared if the voltage between pins RL1 and RL2
drops below the limits programmed via bits RIL2...0 and the received
data stream has no transition for a period defined in the PCD register.
The threshold where no signal is declared is programmable by the
RIL2...0 bits, see
1
Enable Frame Synchronization Pulse
RIL2
H
Normal operation
Local loop active. The local loopback mode disconnects the
receive lines RL1/RL2 or RDIP/RDIN from the receiver. Instead
of the signals coming from the line the data provided by system
interface are routed through the analog receiver back to the
system interface. The unipolar bit stream is transmitted
undisturbedly on the line. Receiver and transmitter coding must
be identical. Operates in analog and digital line interface mode.
In analog line interface mode data is transferred through the
complete analog receiver.
Slave mode
Master mode on. Setting this bit the DCO-R circuitry is
frequency synchronized with the clock (2.048 MHz) supplied by
SYNC. If this pin is connected to VSS the DCO-R circuitry is
centered and no receive jitter attenuation is performed. The
generated clocks are stable.
The transmit clock is output via pin XCLK.
Pin XCLK provides a 8 kHz frame synchronization pulse which
is active high for one 2 MHz cycle (pulse width = 488 ns).
RIL1
Table 58 "DC Parameters" on page 336
RIL0
214
TCD1
JATT
RL
FALC-LH V1.3
DRS
E1 Registers
0
PEB 2255
for detail.