MMCCMB2107 Freescale, MMCCMB2107 Datasheet - Page 170

no-image

MMCCMB2107

Manufacturer Part Number
MMCCMB2107
Description
Manufacturer
Freescale
Datasheet

Specifications of MMCCMB2107

Lead Free Status / RoHS Status
Not Compliant
Interrupt Controller Module
Technical Data
170
If the AE bit is 0, then each interrupt request is presented with a vector
number. The low five bits of the vector number (4–0) are determined
based on the highest pending priority, with active fast interrupts having
priority over active normal interrupts. The remaining two bits (vector bits
5 and 6) are determined based on whether the interrupt request is a fast
interrupt and the setting of the FVE bit. If FVE is set, then a fast interrupt
request has a vector number different from that of a normal interrupt
request as shown in
If FVE is 0, both normal and fast interrupts requests assigned to priority
levels 0–31 are mapped to vector numbers 32–63 in the vector table. If
FVE is 1, normal interrupt requests assigned to priority levels 0–31 are
mapped to vector numbers 32–63 in the vector table.
If FVE is 1, then fast interrupt requests assigned to priority levels 0–31
are mapped to vector numbers 64–95 in the vector table. See
Freescale Semiconductor, Inc.
For More Information On This Product,
Number
96–127
Vector
32–63
64–95
0–31
Fast Interrupt
Yes
Go to: www.freescale.com
Interrupt Controller Module
No
X
Table 7-4. Fast Interrupt Vector Number
Fixed exceptions (including autovectors)
Table 7-5. Vector Table Mapping
Vectored interrupts (not used)
Table
63 = highest priority
95 = highest priority
Vectored interrupts
Vectored interrupts
32 = lowest priority
64 = lowest priority
7-4.
FVE
Usage
X
0
1
Interrupt Vector
Bits 6:5
Interrupt Vector
01
01
10
MMC2107 – Rev. 2.0
Bits 6:5
00
01
10
11
MOTOROLA
Table
7-5.