TMPM361F10FG Toshiba, TMPM361F10FG Datasheet - Page 584

no-image

TMPM361F10FG

Manufacturer Part Number
TMPM361F10FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM361F10FG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Contact Us
Rom (kbytes)
1024K
Rom Type
Flash
Ram (kbytes)
64K
Number Of Pins
100
Package
LQFP(14Ã?14)
Vcc
3V
Cpu Mhz
64
Ssp (ch) Spi
1
I2c/sio (ch)
3
Uart/sio (ch)
5
Usb
-
Can
-
Ethernet
-
External Bus Interface
Y
Cs/wait Controller (ch)
4
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
8
12-bit Ad Converter
-
16-bit Timer / Counter
16
Motor / Igbt Control
-
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
Y
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM361F10FG
Manufacturer:
Toshiba
Quantity:
10 000
20.4
Description of Operations
20.4.4
20.4.5
20.4.5.1
ized to "0000".
low.
After a reset, ADMOD0<REPEAT,SCAN> is initialized to "00" and ADMOD1<ADCH[3:0]> is initial-
The channels to be converted are selected according to the operation mode of the AD converter as shown be-
activated by setting ADMOD2<HPADCE> to "1".
sion, one of these operation modes must be selected by setting ADMOD0<REPEAT,SCAN> to an appropri-
ate setting. For top-priority AD conversion, only one operation mode can be used: fixed channel single con-
version mode.
MOD4<ADHS>, and top-priority AD conversion can be activated using the HW activation source selec-
ted by ADMOD4<HADHS>. If bits of <ADHS> and <HADHS> are "0", normal and top-priority AD con-
versions are activated in response to the input of a falling edge through the ADTRG pin. If these bits are
"1", normal AD conversion is activated in response to TB6RG0 generated by the 16-bit timer 6, and top-pri-
ority AD conversion is activated in response to TB5RG0 generated by the 16-bit timer 5.
MOD4<HADHTG> to "1" for top-priority AD conversion.
Selecting the Input Channel
AD Conversion Details
1. Normal AD conversion mode
2. Top-priority AD conversion mode
Note 1: When an external trigger is used for the HW activation source of a top-priority AD conversion, an external trig-
Note 2: TMPM361F10FG disables the external trigger used for H/W activation. Therefore "0" cannot be set to
Normal AD conversion is activated by setting ADMOD0<ADS> to "1". Top-priority AD conversion is
Four operation modes are made available to normal AD conversion. In performing normal AD conver-
Normal AD conversion can be activated using the H/W activation source selected by AD-
To permit H/W activation, set ADMOD4<ADHTG> to "1" for normal AD conversion and set AD-
Software activation is still valid even after H/W activation has been permitted.
Starting AD Conversion
MOD2<HPADCH> to an appropriate setting.
・ If the analog input channel is used in a fixed state (ADMOD0<SCAN> = "0")
・ If the analog input channel is used in a scan state (ADMOD0<SCAN> = "1")
One channel is selected from analog input pins from AIN0 through AIN7 by setting AD-
ger cannot be set for activating normal AD conversion H/W.
<HADHS> and <ADHS>.
MOD1<ADCH> to an appropriate setting.
ADSCN to an appropriate setting.
One channel is selected from analog input pins AIN0 through AIN7 by setting AD-
One scan mode is selected from the scan modes by setting ADMOD1 <ADCH> and