DF2148BTE20 Renesas Electronics America, DF2148BTE20 Datasheet - Page 441

IC H8S MCU FLASH 128K 100-QFP

DF2148BTE20

Manufacturer Part Number
DF2148BTE20
Description
IC H8S MCU FLASH 128K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheets

Specifications of DF2148BTE20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SCI, X-Bus
Peripherals
PWM, WDT
Number Of I /o
74
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F2148BTE20
HD64F2148BTE20

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2148BTE20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
All data received?
FER flags in SSR
Start reception
Figure 15.9 Sample Serial Reception Flowchart (1)
Initialization
RDRF = 1
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Section 15 Serial Communication Interface (SCI and IrDA)
Yes
[1]
[2]
[4]
[5]
[3]
[1] SCI initialization:
[2] [3] Receive error processing and break
[4] SCI status check and receive data read:
[5] Serial reception continuation procedure:
Legend:
: Logical OR
Rev. 3.00 Mar 21, 2006 page 385 of 788
The RxD pin is automatically
designated as the receive data input
pin.
detection:
If a receive error occurs, read the
ORER, PER, and FER flags in SSR to
identify the error. After performing the
appropriate error processing, ensure
that the ORER, PER, and FER flags are
all cleared to 0. Reception cannot be
resumed if any of these flags are set to
1. In the case of a framing error, a
break can be detected by reading the
value of the input port corresponding to
the RxD pin.
Read SSR and check that RDRF = 1,
then read the receive data in RDR and
clear the RDRF flag to 0. Transition of
the RDRF flag from 0 to 1 can also be
identified by an RXI interrupt.
To continue serial reception, before the
stop bit for the current frame is
received, read the RDRF flag, read
RDR, and clear the RDRF flag to 0.
However, the RDRF flag is cleared
automatically when the DTC is initiated
by an RXI interrupt and reads data from
RDR.
REJ09B0300-0300