Specifications of UPD70F3771GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CAN, CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3771GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-H, V850ES/JH3-H
14.5 Usage
14.6 Cautions
R01UH0042EJ0400 Rev.4.00
Sep 30, 2010
(1) Disable real-time output.
(2) Perform initialization as follows.
(3) Enable real-time output.
(4) Set the next output value to the RTBH0 and RTBL0 registers by the time the selected transfer trigger is
(5) Sequentially set the next real-time output value to the RTBH0 and RTBL0 registers via interrupt servicing
(1) Prevent the following conflicts by software.
(2) Before performing initialization, disable real-time output (RTPOE0 bit = 0).
(3) Once real-time output has been disabled (RTPOE0 bit = 0), be sure to initialize the RTBH0 and RTBL0 registers
generated
before enabling real-time output again (RTPOE0 bit = 0 → 1).
Clear the RTPC0.RTPOE0 bit to 0.
• Set the alternate-function pins of port 2 or port 5
• Specify the real-time output port mode or port mode in 1-bit units.
• Channel configuration: Select the trigger and valid edge.
• Set the initial values to the RTBH0 and RTBL0 registers
Set the RTPOE0 bit = 1.
corresponding to the selected trigger.
Notes 1. If the RTBH0 and RTBL0 registers are written when the RTPOE0 bit = 0, that value is transferred to
• Conflict between real-time output disable/enable switching (RTPOE0 bit) and the selected real-time output
• Conflict between writing to the RTBH0 and RTBL0 registers in the real-time output enabled status and the
After setting the PFC2.PFC2m bit and PFCE2.PFCE2m bit to the RTO pin, set the PMC2.PMC2m bit to 1 (m = 0
to 3).
After setting the PFC5.PFC5m bit and PFCE5.PFCE5m bit to the RTO pin, set the PMC5.PMC5m bit to 1 (m = 0
to 5).
Set the RTPM0 register.
Set the RTPC0.EXTR0, RTPC0.BYTE0, and RTPC0.RTPEG0 bits.
trigger.
selected real-time output trigger.
2.
Even if the RTBH0 and RTBL0 registers are written when the RTPOE0 bit = 1, data is not transferred to
Note 2
real-time output latches 0H and 0L.
real-time output latches 0H and 0L.
.
CHAPTER 14 REAL-TIME OUTPUT FUNCTION (RTO)
Note 1
.
Page 678 of 1509