D6417729RHF200BV Renesas Electronics America, D6417729RHF200BV Datasheet - Page 718

IC SUPER H MPU ROMLESS 208QFP

D6417729RHF200BV

Manufacturer Part Number
D6417729RHF200BV
Description
IC SUPER H MPU ROMLESS 208QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of D6417729RHF200BV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
200MHz
Connectivity
EBI/EMI, FIFO, IrDA, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
96
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.85 V ~ 2.15 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
208-QFP Exposed Pad, 208-eQFP, 208-HQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D6417729RHF200BV
Manufacturer:
EVERLIGHT
Quantity:
1 000
Part Number:
D6417729RHF200BV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
21.4.3
Scan mode is useful for monitoring analog inputs in a group of one or more channels. When the
ADST bit in the A/D control/status register (ADCSR) is set to 1 by software or external trigger
input, A/D conversion starts on the first channel in the group (AN0 when CH2 = 0, AN4 when
CH2 = 1)). When two or more channels are selected, after conversion of the first channel ends,
conversion of the second channel (AN1 or AN5) starts immediately. A/D conversion continues
cyclically on the selected channels until the ADST bit is cleared to 0. The conversion results are
transferred for storage into the A/D data registers corresponding to the channels.
When the mode or analog input channel must be changed during analog conversion, to prevent
incorrect operation, first clear the ADST bit to 0 to halt A/D conversion. After making the
necessary changes, set the ADST bit to 1. A/D conversion will start again from the first channel
in the group. The ADST bit can be set at the same time as the mode or channel selection is
changed.
Typical operations when three channels (AN0 to AN2) are selected in scan mode are described
next. Figure 21.5 shows a timing diagram for this example.
1. Scan mode is selected (MULTI = 1, SCN = 1), channel group 2 is selected (CH2 = 0), analog
2. When A/D conversion of the first channel (AN0) is completed, the result is transferred into
3. Conversion proceeds in the same way through the third channel (AN2).
4. When conversion of all the selected channels (AN0 to AN2) is completed, the ADF flag is set
5. Steps 2 to 4 are repeated as long as the ADST bit remains set to 1. When the ADST bit is
Rev. 5.0, 09/03, page 670 of 806
input channels AN0 to AN2 are selected (CH1 = 1, CH0 = 0), and A/D conversion is started
(ADST = 1).
ADDRA. Next, conversion of the second channel (AN1) starts automatically.
to 1 and conversion of the first channel (AN0) starts again. If the ADIE bit is set to 1, an ADI
interrupt is requested at this time.
cleared to 0, A/D conversion stops. After that, if the ADST bit is set to 1, A/D conversion
starts again from the first channel (AN0).
Scan Mode (MULTI = 1, SCN = 1)

Related parts for D6417729RHF200BV