Specifications of UPD70F3786GJ-GAE-AX

Core Processor
RISC
Core Size
32-Bit
Speed
50MHz
Connectivity
CAN, CSI, EBI/EMI, Ethernet, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
100
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
124K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
<R>
22.4 Cautions
1184
(1) Clock accuracy
(2) Stopping the USB clock
To operate the USB function controller, the internal clock (6 MHz external clock × internal clock multiplied by 8
= 48 MHz internal clock) or external clock (external clock input to EXCLK pin (f
the USB clock. When the internal clock is used as the USB clock, use a resonator with an accuracy of 6 MHz
±500 ppm (max.). When the external clock is used, apply a clock with an accuracy of 48 MHz ±500 ppm
(max.) to the EXCLK pin. If the USB clock accuracy drops, the transmission data cannot satisfy the USB rating.
When the main clock (f
the USB function controller, be sure to stop the USB function controller (by setting bits 1 and 0 of the
UFCKMSK register to 1) first before stopping the main clock (f
If the main clock (f
due to noise in the clock pulse when the main clock (f
Similarly, when an external clock whose signal is input from the EXCLK pin is selected as the USB function
controller clock, measures must be taken to prevent noise from being generated in the clock pulse by the
external circuit. If this is not feasible, then the USB function controller must be stopped first before stopping the
main clock (f
XX
).
XX
) is stopped without first stopping the USB function controller, a malfunction might occur
XX
CHAPTER 22 USB FUNCTION CONTROLLER (USBF)
) has been selected as the USB function controller clock and it is necessary to stop
User’s Manual U19601EJ2V0UD
XX
) is restarted.
XX
).
USB
= 48 MHz)) must be used as