UPD70F3786GJ-GAE-AX Renesas Electronics America, UPD70F3786GJ-GAE-AX Datasheet - Page 1229

no-image

UPD70F3786GJ-GAE-AX

Manufacturer Part Number
UPD70F3786GJ-GAE-AX
Description
MCU 32BIT V850ES/JX3-E 144-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Er
Datasheet

Specifications of UPD70F3786GJ-GAE-AX

Core Processor
RISC
Core Size
32-Bit
Speed
50MHz
Connectivity
CAN, CSI, EBI/EMI, Ethernet, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
100
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
124K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
(12) UF0 INT status 1 register (UF0IS1)
UF0IS1
Bit position
This register indicates the interrupt source. If the contents of this register are changed, the EPCINT0B signal
becomes active.
This register is read-only, in 8-bit units.
If an interrupt request (INTUSBF0) is generated from USBF, the FW must read this register to identify the
interrupt source.
Each bit of this register is forcibly cleared to 0 when 0 is written to the corresponding bit of the UF0IC1 register.
However, the SUCES and STG bits of the UF0IS1 register are automatically cleared to 0 when the next
SETUP token has been received.
Caution In the USBF, multiple interrupt sources, such as Bus Reset, Resume, and Short, are ORed
6
5
7
0
internally and are issued as a single interrupt request (INTUSBF0). Therefore, in the case of
the occurrence of multiple interrupt sources, they are ORed and issued as an INTUSBF0
interrupt request.
For example, if a Bus Reset interrupt source and Resume interrupt source occur, the two
sources are ORed and an INTUSBF0 interrupt request is issued.
Under these conditions, if the Bus Reset interrupt source is cleared to 0 (UF0IC0.BUSRSTC
= 0), the V850ES/JH3-E or V850ES/JJ3-E internal INTUSBF0 interrupt request may remain set
to 1 since the Resume interrupt source will still be remaining. The new interrupt request flag
(US0BIC.US0BIF), therefore, might not be set to 1.
In this case, after performing clear processing for each interrupt request with the INTUSBF0
interrupt servicing routine, confirm the flag status for the UF0IS0 and UF0IS1 registers again,
and if there are any interrupt sources with flags set to 1, perform flag clearing (only the
applicable bits need to be cleared (do not perform a batch clearing)).
E0IN
E0INDT
Bit name
E0IN
6
CHAPTER 22 USB FUNCTION CONTROLLER (USBF)
E0INDT
This bit indicates that an IN token for Endpoint0 has been received and that the
hardware has automatically transmitted NAK.
This bit indicates that data has been correctly transmitted from the UF0E0W register.
Data is transmitted in synchronization with the IN token next to the one that set the
EP0NKW bit of the UF0E0N register to 1. This bit is automatically set to 1 by hardware
when the host correctly receives that data. It is also set to 1 even if the data is a Null
packet. This bit is automatically cleared to 0 by hardware when the first write access is
made to the UF0E0W register.
5
1: IN token is received and NAK is transmitted (interrupt request is generated).
0: IN token is not received (default value).
1: Transmission from UF0E0W register is completed (interrupt request is generated).
0: Transmission from UF0E0W register is not completed (default value).
E0ODT
4
User’s Manual U19601EJ2V0UD
SUCES
3
STG
2
Function
PROT
1
CPU
DEC
0
00200022H
Address
After reset
00H
1227
(1/2)

Related parts for UPD70F3786GJ-GAE-AX