AT91SAM9G45-EKES Atmel, AT91SAM9G45-EKES Datasheet - Page 845

KIT EVAL FOR AT91SAM9G45

AT91SAM9G45-EKES

Manufacturer Part Number
AT91SAM9G45-EKES
Description
KIT EVAL FOR AT91SAM9G45
Manufacturer
Atmel
Series
AT91SAM Smart ARMr
Type
MCUr

Specifications of AT91SAM9G45-EKES

Contents
Board
Processor To Be Evaluated
SAM9G45
Data Bus Width
32 bit
Interface Type
I2C, SPI, UART
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
1.8 V to 3.3 V
For Use With/related Products
AT91SAM9G45
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4626953
38.5.8.14
845
AT91SAM9G45
Isochronous Endpoint Handling: OUT Example
Example:
The user can ascertain the bank status (free or busy), and the toggle sequencing of the data
packet for each bank with the UDPHS_EPTSTAx register in the three bit fields as follows:
This is particularly useful in case of a missing data packet.
If the inter-packet delay between the OUT token and the Data is greater than the USB standard,
then the ISO-OUT transaction is ignored. (Payload data is not written, no interrupt is generated
to the CPU.)
If there is a data CRC (Cyclic Redundancy Check) error, the payload is, none the less, written in
the endpoint. The ERR_CRISO flag is set in UDPHS_EPTSTAx register.
If the endpoint is already full, the packet is not written in the DPRAM. The ERR_FL_ISO flag is
set in UDPHS_EPTSTAx.
If the payload data is greater than the maximum size of the endpoint, then the ERR_OVFLW flag
is set. It is the task of the CPU to manage this error. The data packet is written in the endpoint
(except the extra data).
If the host sends a Zero Length Packet, and the endpoint is free, no data is written in the end-
point, the RX_BK_RDY flag is set, and the BYTE_COUNT field in UDPHS_EPTSTAx register is
null.
The FRCESTALL command bit is unused for an isochonous endpoint.
Otherwise, payload data is written in the endpoint, the RX_BK_RDY interrupt is generated and
the BYTE_COUNT in UDPHS_EPTSTAx register is updated.
• If NB_TRANS = 3, the sequence should be either
• If NB_TRANS = 2, the sequence should be either
• If NB_TRANS = 1, the sequence should be
• TOGGLESQ_STA: PID of the data stored in the current bank
• CURRENT_BANK: Number of the bank currently being accessed by the microcontroller.
• BUSY_BANK_STA: Number of busy bank
– MData0
– MData0/Data1
– MData0/Data1/Data2
– MData0
– MData0/Data1
– Data0
6438F–ATARM–21-Jun-10