TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 18

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Power
1.5V
Power
3.3V
1.5-V rails should be
turned on first,
followed by the 3.3-V
rails.
PWE terminal
DVCC3A
DVCC3B
AVCC
DVCC1A
DVCC1B
DVCC1C
RESET
Note1: Although it is possible to turn on or off the 1.5-V and 3.3-V power supply rails simultaneously, it may cause
Note2: In the power-on sequence, the 3.3-V power supply rails must not be turned on before the ones of 1.5-V . In the
3.3V power with 1.5V power is supplied.
This LSI has the restriction for the order of supplying power. Be sure to supply external
When Powering on
external pins to temporarily become unstable. Therefore, if there is any possibility that this would affect
peripheral devices connected with the TMP92CF26A, external power supplies should be turned on or off while
the internal power supplies are stable, as indicated by the heavy lines in the diagram above.
power -off sequence, the 3.3-V power supply rails must not be turned off after the ones of 1.5-V.
Power should rise and
stabilizes within 100 ms.
Figure 3.1.2 Power on Reset Timing Example
High-frequency Oscillation Stabilizing Time
+20 system clock cycles
92CF26A-17
Power Cut Mode (PMC)
Power should fall and
stabilizes within 100 ms.
When Powering off
3.3-V rails should be
turned off first, followed by
the 1.5-V rails.
TMP92CF26A
2007-11-21