TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 319

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Loading to TB0CP0H/L
Loading to TB0CP1H/L
Count clock
(Prescaler ouptut clock)
TB0IN0 pin input
(External pulse)
INT6
Note: Only in this pulse width measuring mode(TB0MOD<TB0CPM1:0> “10”), external interrupt INT6 occurs at the
falling edge of TB0IN0 pin input. In other modes, it occurs at the rising edge.
3.
keeping the 16 bit timer/event counter counting (free-running) with the internal
clock input, the external pulse is input through the TB0IN0 pin. Then the capture
function is used to load the UC10 values into TB0CP0H/L and TB0CP1H/L at the
rising edge and falling edge of the external trigger pulse respectively. The
interrupt INT6 occurs at the falling edge of TB0IN0.
TB0CP0H/L and TB0CP1H/L and the internal clock cycle.
TB0CP0H/L and TB0CP1H/L is 100, the pulse width will be 100 × 0.8[μs] =80μs
specified by the clock source can be measured by changing software.
first C1 and the second C0 at the second INT6 interrupt and the internal clock
cycle together.
Pulse width measurement
This mode allows measuring the H level width of an external pulse. While
The pulse width is obtained from the difference between the values of
For example, if the internal clock is 0.8[us] and the difference between
Additionally, the pulse width which is over the UC10 maximum count time
The width of L level can be measured by multiplying the difference between the
C1
Figure 3.13.15 Pulse Width Measurement
C1
92CF26A-318
C2
C2
C1
C2
TMP92CF26A
2007-11-21