AT91SAM9G45-CU Atmel, AT91SAM9G45-CU Datasheet - Page 841

MCU ARM9 324-TFBGA

AT91SAM9G45-CU

Manufacturer Part Number
AT91SAM9G45-CU
Description
MCU ARM9 324-TFBGA
Manufacturer
Atmel
Series
AT91SAMr

Specifications of AT91SAM9G45-CU

Core Processor
ARM9
Core Size
16/32-Bit
Speed
400MHz
Connectivity
EBI/EMI, Ethernet, I²C, IrDA, MMC, SPI, SSC, UART/USART, USB
Peripherals
AC'97, DMA, I²S, LCD, POR, PWM, WDT
Number Of I /o
160
Program Memory Size
64KB (64K x 8)
Program Memory Type
ROM
Ram Size
128K x 8
Voltage - Supply (vcc/vdd)
0.9 V ~ 1.1 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
324-TFBGA
Processor Series
AT91SAMx
Core
ARM926EJ-S
Data Bus Width
32 bit
Data Ram Size
64 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
800 MHz
Number Of Programmable I/os
160
Number Of Timers
5
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
Controller Family/series
AT91
No. Of I/o's
160
Ram Memory Size
64KB
Cpu Speed
400MHz
No. Of Timers
2
Rohs Compliant
Yes
For Use With
AT91SAM9G45-EKES - KIT EVAL FOR AT91SAM9G45
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9G45-CU
Manufacturer:
ATMEL
Quantity:
1 000
Part Number:
AT91SAM9G45-CU
Manufacturer:
Atmel
Quantity:
31
Part Number:
AT91SAM9G45-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM9G45-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
AT91SAM9G45-CU
Quantity:
340
Part Number:
AT91SAM9G45-CU-999
Manufacturer:
Atmel
Quantity:
10 000
841
AT91SAM9G45
the required number of packets per microframe, otherwise, the host will notice a sequencing
problem.
A response should be made to the first token IN recognized inside a microframe under the fol-
lowing conditions:
At the end of a microframe in which at least one data bank has been transmitted, if less than
NB_TRANS banks have been validated for that microframe, an error condition is flagged
(ERR_TRANS is set in UDPHS_EPTSTAx).
Cases of Error (in UDPHS_EPTSTAx)
• If at least one bank has been validated, the correct DATAx corresponding to the programmed
• If no bank is validated yet, the default DATA0 ZLP is answered and underflow is flagged
• If no data bank has been validated at the time when a response should be made for the
• If no data bank has been validated at the time when a response should be made for the last
• If at the end of a microframe no valid token IN has been recognized, no data bank is flushed
• ERR_FL_ISO: There was no data to transmit inside a microframe, so a ZLP is answered by
• ERR_FLUSH: At least one packet has been sent inside the microframe, but the number of
• ERR_TRANS: At least one packet has been sent inside the microframe, but the number of
• ERR_FL_ISO + ERR_FLUSH: At least one packet has been sent inside the microframe, but
• ERR_FL_ISO + ERR_TRANS: At least one packet has been sent inside the microframe, but
• ERR_FLUSH + ERR_TRANS: The first token IN has been answered and it was the only one
Number Of Transactions per Microframe (NB_TRANS) should be answered. In case of a
subsequent missed or corrupted token IN inside the microframe, the USB 2.0 Core available
data bank(s) that should normally have been transmitted during that microframe shall be
flushed at its end. If this flush occurs, an error condition is flagged (ERR_FLUSH is set in
UDPHS_EPTSTAx).
(ERR_FL_ISO is set in UDPHS_EPTSTAx). Then, no data bank is flushed at microframe
end.
second transaction of NB_TRANS = 3 transactions microframe, a DATA1 ZLP is answered
and underflow is flagged (ERR_FL_ISO is set in UDPHS_EPTSTAx). If and only if remaining
untransmitted banks for that microframe are available at its end, they are flushed and an error
condition is flagged (ERR_FLUSH is set in UDPHS_EPTSTAx).
programmed transaction of a microframe, a DATA0 ZLP is answered and underflow is flagged
(ERR_FL_ISO is set in UDPHS_EPTSTAx). If and only if the remaining untransmitted data
bank for that microframe is available at its end, it is flushed and an error condition is flagged
(ERR_FLUSH is set in UDPHS_EPTSTAx).
and no error condition is reported.
default.
token IN received is lesser than the number of transactions actually validated (TX_BK_RDY)
and likewise with the NB_TRANS programmed.
token IN received is lesser than the number of programmed NB_TRANS transactions and the
packets not requested were not validated.
the data has not been validated in time to answer one of the following token IN.
the data has not been validated in time to answer one of the following token IN and the data
can be discarded at the microframe end.
received, a second bank has been validated but not the third, whereas NB_TRANS was
waiting for three transactions.
6438F–ATARM–21-Jun-10

Related parts for AT91SAM9G45-CU