MPC8313ECZQADDC Freescale Semiconductor, MPC8313ECZQADDC Datasheet - Page 592

no-image

MPC8313ECZQADDC

Manufacturer Part Number
MPC8313ECZQADDC
Description
Microprocessors - MPU 8313 REV2.2 PB ENC EXT
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MPC8313ECZQADDC

Processor Series
MPC8313E
Core
e300
Data Bus Width
16 bit
Maximum Clock Frequency
133 MHz
Program Memory Size
16 KB
Data Ram Size
16 KB
Interface Type
I2C
Mounting Style
SMD/SMT
Package / Case
PBGA
Number Of Programmable I/os
32
Number Of Timers
4
PCI Bus Interface
13-10
PCI_RESET_OUT
PCI_SERR
PCI_STOP
Signal
MPC8313E PowerQUICC™ II Pro Integrated Processor Family Reference Manual, Rev. 2
Table 13-3. PCI Interface Signals—Detailed Signal Descriptions (continued)
I/O
I/O PCI system error
I/O PCI stop.
O
O
O
I
I
PCI reset. This signal is used only in host mode. It should be left unconnected in agent mode.
Outputs for the bi-directional system error.
Inputs for the bi-directional system error.
Outputs for the bi-directional stop.
Inputs for the bi-directional stop.
Meaning
Meaning
Meaning
Meaning
Meaning
Timing Assertion/Negation—As specified by PCI Local Bus Specification Rev 2.3
Timing Assertion/Negation—As specified by PCI Local Bus Specification Rev 2.3
Timing Assertion/Negation—As specified by PCI Local Bus Specification Rev 2.3
Timing Assertion/Negation—As specified by PCI Local Bus Specification Rev 2.3
Timing Assertion/Negation—As specified by PCI Local Bus Specification Rev 2.3
State
State
State
State
State
Asserted—Devices on the PCI bus are in reset.
Negated—Devices on the PCI bus operate normally.
Asserted—An address parity error, a target-abort (when this PCI controller is acting as
Negated—No error.
Asserted—A device (other than this PCI controller) has detected a catastrophic error.
Negated—No error.
Asserted—The PCI controller, acting as a PCI target, is requesting that the initiator stop
Negated—The current transaction can continue.
Asserted—A target is requesting that this PCI controller, as the initiator, stop the current
Negated—The current transaction can continue.
the initiator), or some other system error (where the result is a catastrophic error)
was detected.
the current transaction.
transaction.