HD64F3029XBL25V Renesas Electronics America, HD64F3029XBL25V Datasheet - Page 528

MCU 5V 512K,PB-FREE 100-TQFP

HD64F3029XBL25V

Manufacturer Part Number
HD64F3029XBL25V
Description
MCU 5V 512K,PB-FREE 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD64F3029XBL25V

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Figure 13.12 Sample Flowchart for Receiving Multiprocessor Serial Data (1)
No
No
No
Read ORER and FER flags
Read ORER and FER flags
Read receive data from RDR
Set MPIE bit to 1 in SCR
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
Read RDRF flag in SSR
Read RDRF flag in SSR
Finished receiving?
FER ORER = 1
FER ORER = 1
Start receiving
RDRF = 1
RDRF = 1
Own ID?
Initialize
in SSR
in SSR
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error handling
(1)
(2)
(3)
(continued on next page)
(4)
(5)
(1)
(2)
(3)
(4)
(5)
SCI initialization:
the receive data input function of the
RxD pin is selected automatically.
ID receive cycle:
set the MPIE bit to 1 in SCR.
SCI status check and ID check:
read SSR, check that the RDRF flag
is set to 1, then read data from RDR
and compare it with the processor's
own ID. If the ID does not match, set
the MPIE bit to 1 again and clear the
RDRF flag to 0. If the ID matches,
clear the RDRF flag to 0.
SCI status check and data receiving:
read SSR, check that the RDRF flag
is set to 1, then read data from RDR.
Receive error handling and break
detection:
if a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After executing the
necessary error handling, clear the
ORER and FER flags both to 0.
Receiving cannot resume while either
the ORER or FER flag remains set to
1. When a framing error occurs, the
RxD pin can be read to detect the
break state.
Rev. 2.0, 06/04, page 499 of 980

Related parts for HD64F3029XBL25V