Specifications of HD64F3029XBL25V

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
The specified address should match the unit for programming of data. For example, when the
programming is in 128-byte units, the lower byte of the address should be H'00 or H'80.
When there are less than 128 bytes of data to be programmed, the host should fill the rest with
H'FF.
Sending the 128-byte programming command with the address of H'FFFFFFFF will stop the
programming operation. The boot program will interpret this as the end of the programming and
wait for selection of programming or erasing.
Command H'50
Response
Error
response
Erasure is performed with the erasure selection and block erasure command.
Firstly, erasure is selected by the erasure selection command and the boot program then erases the
specified block. The command should be repeatedly executed if two or more blocks are to be
erased. Sending a block-erasure command from the host with the block number H'FF will stop the
erasure operating. On completion of erasing, the boot program will wait for selection of
programming or erasing.
The sequences of the issuing of erasure selection commands and the erasure of data are shown in
figure 18.28.
Erasure
Command, H'50, (1 byte) : 128-byte programming
Programming Address (4 bytes) : End code is H'FF, H'FF, H'FF, H'FF.
SUM (1 byte) : Checksum
Response: H'06 (1 byte): Response to 128-byte programming
On completion of programming, the boot program will return ACK.
Error Response, H'D0, (1 byte) : Error response for 128-byte programming
ERROR : (1 byte) : Error code
H'06
H'D0
H'53 : Programming error
H'11 : Checksum error
H'53 : Programming error
An error has occurred in programming and programming cannot be
continued.
A programming error has occurred and programming cannot be
continued.
Address
ERROR
Rev. 2.0, 06/04, page 665 of 980
SUM

Related parts for HD64F3029XBL25V