tmp19a44fda TOSHIBA Semiconductor CORPORATION, tmp19a44fda Datasheet - Page 299

no-image

tmp19a44fda

Manufacturer Part Number
tmp19a44fda
Description
32bit Tx System Risc
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp19a44fdaXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG 040A
Manufacturer:
TOSHIBA
Quantity:
12 087
Part Number:
tmp19a44fdaXBG 041A
Manufacturer:
TOSHIBA
Quantity:
16 800
Part Number:
tmp19a44fdaXBG 7GR3
Manufacturer:
TOSHIBA
Quantity:
25 031
Part Number:
tmp19a44fdaXBG 7H36
Manufacturer:
SMD
Quantity:
3 200
Part Number:
tmp19a44fdaXBG7NG8
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp19a44fdaXBG7PA2
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
11. 16-bit Timer/Event Counters (TMRBs)
channels.
16-bit Timer/Event Counters (TMRBs)
Each of the eighteen channels (TMRB0 through TMR11) has a multi-functional, 16-bit timer/event counter.
TMRBs operate in the following four operation modes:
The use of the capture function allows TMRBs to operate in three other modes:
Each channel consists of a 16-bit up-counter, two 16-bit timer registers (double-buffered), two 16-bit capture
registers, two comparators, a capture input control, a timer flip-flop and its associated control circuit. Timer
operation modes and the timer flip-flop are controlled by a 13-byte register.
Each channel (TMRB0 through TMRB11) functions independently and while the channels operate in the same
way, there are differences in their specifications as shown in Table 11.1. Therefore, the operational descriptions
here are for TMRB0 only.
(1) The flip-flop output of TMRB 0, TMRB 8 and TMRB 10 can be used as the capture trigger of other
(2) The start trigger of the timer synchronous mode (with TBxRUN)
16-bit interval timer mode
16-bit event counter mode
16-bit programmable square-wave output (PPG) mode (simultaneous output in units of four channels can
be programmed)
Timer synchronous mode
The channels shown below are used as the capture or start trigger.
• Frequency measurement mode
• Pulse width measurement mode
• Time difference measurement mode
TB0OUT => available for TMRB 1 through TMRB 7
TB8OUT => available for TMRB 9 through TMRB F
TB10OUT => available for TMRB 11
TMRB0 => can start TMRB 0 through TMRB 3 synchronously
TMRB4 => can start TMRB 4 through TMRB 7 synchronously
TMRB8 => can start TMRB 8, 9, A and B synchronously
TMRBC => can start TMRB C through TMRB F synchronously
TMRB10 => can start TMRB 10 through TMRB 11 synchronously
TMP19A44(rev1.3) 11-1