• User break before instruction execution
• User break after instruction execution
Table 7.4
(4)
If a CPU address error occurs in the repeat control period, the exception is accepted but an
exception code (H'070) indicating the repeat loop period is specified in the EXPEVT. If a CPU
address error occurs in instructions following a repeat detection instruction to repeat end
instruction, an exception code for instruction access or data access is specified in the EXPEVT.
The SPC is saved according to the description, SPC Saved by an Exception in Repeat Control
Period in section 7.4.3, Exception in Repeat Control Period.
After the CPU address error exception processing, the repeat control cannot be returned correctly.
To execute a repeat loop correctly, care must be taken not to generate a CPU address error in the
repeat control period.
Note: In a repeat loop consisting of one to three instructions, some restrictions apply to repeat
Exception Type
Interrupt
DMA address error
User break before instruction execution
User break after instruction execution
A user break before instruction execution is accepted at instruction [B], and an address of
instruction [B] is saved in the SPC. This exception cannot be accepted at instruction [C] but
the exception request is retained until an instruction [A] or [B] is executed at the next time.
Then, the exception request is accepted before an instruction [A] or [B] is executed. In this
case, an address of instruction [A] or [B] is saved in the SPC.
A user break after instruction execution cannot be accepted at instructions [B] and [C] but the
exception request is retained until an instruction [A] or [B] is executed at the next time. Then,
the exception request is accepted before an instruction [A] or [B] is executed. In this case, an
address of instruction [A] or [B] is saved in the SPC.
CPU Address Error in Repeat Control Period
detection instructions and all the remaining instructions. In a repeat loop consisting of four
or more instructions, restrictions apply to only the three instructions that include a repeat
end instruction. The restriction occurs when SR.RC[11:0] ≥ 1.
Exception Acceptance in the Repeat Loop
Instruction [B]
Not accepted
Not accepted
Accepted
Not accepted
Rev. 3.00 Jan. 18, 2008 Page 239 of 1458
Section 7 Exception Handling
Instruction [C]
Not accepted
Not accepted
Not accepted
Not accepted
REJ09B0033-0300