D12321VF25V Renesas Electronics America, D12321VF25V Datasheet - Page 690

IC H8S/2300 MCU ROMLESS 128QFP

D12321VF25V

Manufacturer Part Number
D12321VF25V
Description
IC H8S/2300 MCU ROMLESS 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12321VF25V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
86
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
D12321VF25V
Manufacturer:
Renesas
Quantity:
675
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 14 Serial Communication Interface (SCI)
14.5
The following points should be noted when using the SCI.
Relation between Writes to TDR and the TDRE Flag: The TDRE flag in SSR is a status flag
that indicates that transmit data has been transferred from TDR to TSR. When the SCI transfers
data from TDR to TSR, the TDRE flag is set to 1.
Data can be written to TDR regardless of the state of the TDRE flag. However, if new data is
written to TDR when the TDRE flag is cleared to 0, the data stored in TDR will be lost since it has
not yet been transferred to TSR. It is therefore essential to check that the TDRE flag is set to 1
before writing transmit data to TDR.
Operation when Multiple Receive Errors Occur Simultaneously: If a number of receive errors
occur at the same time, the state of the status flags in SSR is as shown in table 14.13. If there is an
overrun error, data is not transferred from RSR to RDR, and the receive data is lost.
Table 14.13 State of SSR Status Flags and Transfer of Receive Data
RDRF
1
0
0
1
1
0
1
Notes:
Rev.6.00 Sep. 27, 2007 Page 658 of 1268
REJ09B0220-0600
X : Receive data is not transferred from RSR to RDR.
SSR Status Flags
ORER
1
0
0
1
1
0
1
Usage Notes
: Receive data is transferred from RSR to RDR.
FER
0
1
0
1
0
1
1
0
0
1
1
PER
0
1
1
Receive Data Transfer
from RSR to RDR
X
X
X
X
Receive Error Status
Overrun error
Framing error
Parity error
Overrun error + framing error
Overrun error + parity error
Framing error + parity error
Overrun error + framing error +
parity error

Related parts for D12321VF25V