D12321VF25V Renesas Electronics America, D12321VF25V Datasheet - Page 713

IC H8S/2300 MCU ROMLESS 128QFP

D12321VF25V

Manufacturer Part Number
D12321VF25V
Description
IC H8S/2300 MCU ROMLESS 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12321VF25V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
86
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
D12321VF25V
Manufacturer:
Renesas
Quantity:
675
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
The operation sequence is as follows.
[1] When the data line is not in use it is in the high-impedance state, and is fixed high with a pull-
[2] The transmitting station starts transfer of one frame of data. The data frame starts with a start
[3] With the smart card interface, the data line then returns to the high-impedance state. The data
[4] The receiving station carries out a parity check.
[5] If the transmitting station does not receive an error signal, it proceeds to transmit the next data
Block Transfer Mode: The operation sequence in block transfer mode is as follows.
[1] When the data line is not in use it is in the high-impedance state, and is fixed high with a pull-
[2] The transmitting station starts transfer of one frame of data. The data frame starts with a start
[3] With the smart card interface, the data line then returns to the high-impedance state. The data
[4] The receiving station carries out a parity check, but does not output an error signal even if an
[5] The transmitting station proceeds to transmit the next data frame.
up resistor.
bit (Ds, low-level), followed by 8 data bits (D0 to D7) and a parity bit (Dp).
line is pulled high with a pull-up resistor.
If there is no parity error and the data is received normally, the receiving station waits for
reception of the next data.
If a parity error occurs, however, the receiving station outputs an error signal (DE, low-level)
to request retransmission of the data. After outputting the error signal for the prescribed length
of time, the receiving station places the signal line in the high-impedance state again. The
signal line is pulled high again by a pull-up resistor.
frame.
If it does receive an error signal, however, it returns to step [2] and retransmits the data in
which the error occurred.
up resistor.
bit (Ds, low-level), followed by 8 data bits (D0 to D7) and a parity bit (Dp).
line is pulled high with a pull-up resistor.
error has occurred. Since subsequent receive operations cannot be carried out if an error
occurs, the error flag must be cleared to 0 before the parity bit for the next frame is received.
Rev.6.00 Sep. 27, 2007 Page 681 of 1268
Section 15 Smart Card Interface
REJ09B0220-0600