Specifications of D12321VF25V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
86
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
D12321VF25V
Manufacturer:
Renesas
Quantity:
675
Part Number:
D12321VF25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 19 ROM
19.29.5 Auto-Program Mode
• In auto-program mode, 128 bytes are programmed simultaneously. For this purpose, 128
• A 128-byte data transfer must be performed even if writing fewer than 128 bytes; in this case,
• The lower 7 bits of the transfer address must be held low. If an invalid address is input,
• Memory address transfer is executed in the second cycle (figure 19.82). Do not perform
• Do not perform a command write during a programming operation.
• Perform one auto-programming operation for a 128-byte block for each address. One or more
• Confirm normal end of auto-programming by checking I/O
• Status polling I/O
Rev.6.00 Sep. 27, 2007 Page 898 of 1268
REJ09B0220-0600
consecutive byte data transfers should be performed.
H'FF data must be written to the extra addresses.
memory programming will be started but a programming error will occur.
transfer later than the second cycle.
additional programming operations cannot be carried out on address blocks that have already
been programmed.
can also be used for this purpose (the I/O
auto-program operation).
the next command write has not been performed, reading is possible by enabling CE and OE.
6
and I/O
7
information is retained until the next command write. As long as
7
status polling pin is used to identify the end of an
6
. Alternatively, status read mode