EFM32G200F16 Energy Micro, EFM32G200F16 Datasheet - Page 290

MCU 32BIT 16KB FLASH 32-QFN

EFM32G200F16

Manufacturer Part Number
EFM32G200F16
Description
MCU 32BIT 16KB FLASH 32-QFN
Manufacturer
Energy Micro
Series
Geckor
Datasheets

Specifications of EFM32G200F16

Core Processor
ARM® Cortex-M3™
Core Size
32-Bit
Speed
32MHz
Connectivity
EBI/EMI, I²C, IrDA, SmartCard, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
24
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.8 V
Data Converters
A/D 4x12b, D/A 1x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad
Processor Series
EFM32G200
Core
ARM Cortex-M3
Data Bus Width
32 bit
Data Ram Size
8 KB
Interface Type
I2C, UART
Maximum Clock Frequency
32 MHz
Number Of Programmable I/os
24
Number Of Timers
2
Operating Supply Voltage
1.8 V to 3.8 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
21.3.3.2.4 Double Mode
2010-09-06 - d0001_Rev1.00
Figure 21.4. LETIMER Buffered Repeat State Machine
The Double repeat mode works much like the one-shot repeat mode. The difference is that, where the
one-shot mode counts as long as LETIMERn_REP0 is larger than 0, the double mode counts as long as
either LETIMERn_REP0 or LETIMERn_REP1 is larger than 0. As an example, say LETIMERn_REP0
is 3 and LETIMERn_REP1 is 10 when the timer is started. If no further interaction is done with the
timer, LETIMERn_REP0 will now be decremented 3 times, and LETIMERn_REP1 will be decremented
10 times. The timer counts a total of 10 times, and LETIMERn_REP0 is 0 after the first three timer
underflows and stays at 0. LETIMERn_REP0 and LETIMERn_REP1 can be written at any time. After a
write to either of these, the timer is guaranteed to underflow at least the written number of times if the
timer is running. Use the Double repeat mode to generate output on both the LETIMER outputs at the
same time. The state machine for this repeat mode can be seen in Figure 21.5 (p. 291) .
CNT = CNT - 1
CNT = TOP*
CNT = TOP* *
If (BUFTOP)
REP0 = REP1
REP1
COMP0 = COMP1
USED
= 1
NO
NO
NO
NO
REP0 = = 0
REP1 = = 0
CNT = = 0
START
YES
YES
YES
YES
If (COMP0TOP)
Else
TOP*
TOP* = COMP0
TOP* = 0xFFFF
NO
! REP1
...the world's most energy friendly microcontrollers
290
USED
RUNNING
CNT = = 0
REP0 < 2
YES
YES
YES
and ! REP1 ! = 0
NO
Wait for positive clock edge
NO
TOP* *
If (! COMP0TOP)
Else if (BUFTOP)
Else
NO
YES
TOP* * = 0xFFFF
TOP* * = COMP1
TOP* * = COMP0
CNT = CNT - 1
CNT = TOP*
If (! START)
CNT = TOP*
If (BUFTOP)
REP0 = REP1
REP1
STOP = 1
REP0 = 0
COMP0 = COMP1
REP0 = REP0 - 1
USED
www.energymicro.com
= 1
If (STOP)
Else if (START)
End if
START = 0
STOP = 0
RUNNING = 0
RUNNING = 1

Related parts for EFM32G200F16