OM13008,598 NXP Semiconductors, OM13008,598 Datasheet - Page 202

no-image

OM13008,598

Manufacturer Part Number
OM13008,598
Description
BOARD LPC XPRESSO LPC122X
Manufacturer
NXP Semiconductors
Series
LPCXpressor
Datasheets

Specifications of OM13008,598

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-6642
OM13008
NXP Semiconductors
UM10441
User manual
11.10.2 Master Receiver mode
In the master receiver mode, a number of data bytes are received from a slave transmitter
(see
START condition has been transmitted, the interrupt service routine must load DAT with
the 7-bit slave address and the data direction bit (SLA+R). The SI bit in CON must then be
cleared before the serial transfer can continue.
When the slave address and the data direction bit have been transmitted and an
acknowledgment bit has been received, the serial interrupt flag (SI) is set again, and a
number of status codes in STAT are possible. These are 0x40, 0x48, or 0x38 for the
master mode and also 0x68, 0x78, or 0xB0 if the slave mode was enabled (AA = 1). The
appropriate action to be taken for each of these status codes is detailed in
a repeated START condition (state 0x10), the I
transmitter mode by loading DAT with SLA+W.
Figure
23). The transfer is initialized as in the master transmitter mode. When the
All information provided in this document is subject to legal disclaimers.
Rev. 1.1 — 10 March 2011
2
Chapter 11: LPC122x I2C-bus controller
C block may switch to the master
UM10441
© NXP B.V. 2011. All rights reserved.
Table
200. After
202 of 442

Related parts for OM13008,598